FALMEC Mercurio 60 Livret D'instructions page 29

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

- Once you have found the best position, place the bracket on the wall (L),
- With a spirit level, verify the horizontal alignment and mark 2 drilling points at the ends of the
bar.
- Drill the holes, insert n. 2 expansion bolts of 4mm ø and fasten the bracket (L) with the relative
screws.
- Tighten the extension (H) to the bracket (L) using screws (M).
- Put the metal filters back in place and power (electrical) the hood in accordance with regu-
lations in force (sec. D).
INSTRUCTIONS FOR PULSAR HOOD ASSEMBLY
N3
ISLAND HOOD
Phase 1 (fig. 09-10)
- Remove the fastening screws between the extension and trestle (only for transport).
- Fasten the top trestle (C) to the ceiling using the 6 ø 8 fischers and the supplied relative
screws (V1).
- Determine the required distance between hood and cooker (standard distance 65 cm).
Phase 2 (fig. 11-12)
- Fasten the cone+extension assembly (A+B) to the top trestle (C) using the 6 self-threading
screws (V2), making the bottom trestle (D) slide into the top trestle (C).
- For the exhaust version, determine the optimal height of the fumes exhaust pipe and connect.
For the filter version, the top extension slots must remain free so that the air purified by the
carbon filters can escape.
- Set up the electric connection only once the electric power supply has been cut off.
- Slide the extension (B) up to the top flange of the trestle. Next, rotate it clockwise until it is
hooked onto the flange (fig. 13), then fasten permanently with the supplied M3 metric screw
(V3).
- Power the hood in accordance with regulations in force (see sec. D of the booklet).
WALL-MOUNTED HOOD
Phase 1 (fig. W01-W02-W03-W04)
- Determine the distance (H1) required between hood and cooker (standard distance 65 cm).
- Remove the back panel (A) by removing the cover caps (T) and loosening the relative internal
fastening screws (V1).
- Mark the 4 drilling points F following heights P1 and P2 indicated in Fig.W02 or using the back
panel as a drilling template.
- Fasten the back panel (A) to the wall using the 4 expansion plugs Ø8 mm and the relative
screws (V2) supplied.
- With a spirit level, verify the horizontal and vertical alignment of the back panel.
Phase 2 (fig. W05-W06-W07-W08)
- For the exhaust version, (define the top and bottom output use) determine the optimal length
of the fumes exhaust pipe and connect. To aid the operation, ceiling height permitting, co-
ver B can be temporarily removed by removing the relative fastening screws (V3). Set up
the electric connection only once the electric power supply has been cut off. For the filter
version, make sure that the exhaust on cover B is free so that the air purified by the carbon
filters can escape.
- Hook the hood to the back panel using the 4 hooks (G); make sure the hood descends approx
10 mm, make sure it holds.
- Tighten the two top fastening screws (V1), but not completely.
Lift the hood to the desired position and tighten the top and bottom fastening screws all the
way (V1).
- Power the hood in accordance with regulations in force (see sec. D of the booklet).