No. Description
Heating system
Sets the existing heating system:
• Floor heating, standard (FBH St.)
010
• Floor heating, low energy (FBH NE)
• Radiator (RAD)
• Convector, passive (KON pas)
• Convector, active (KON akt)
Blocking of cooling
020
Deactivates the cooling function.
Operating lock
030
Protects the deactivation of the operating
lock with a PIN.
PIN operating lock
031
Sets the PIN for parameter 30.
External sensor (only Control)
Registration of an external room sensor or
floor sensor. The registration of a room sen-
040
sor deactivates the internal sensor. If a floor
sensor is used, the minimum floor tempera-
ture can be set via the Settings menu in the
function "External floor sensor".
Correction of actual temperature of
external sensor
041
(only Control)
Corrects a deviating measurement of the ac-
tual temperature.
Duration of the display illumination
Sets the duration of further illumination of
050
the display after use.
Service menu
Setting
0 = FBH St.
1 = FBH NE
2 = RAD
3 = KON pas
4 = KON akt
Standard: 0
0 = activated
1 = deactivated
Standard: 0
0 = deactivated
1 = activated
Standard: 0
0 ... 9999
Standard: 0000
0 = no external
sensor
1 = room sensor
2 = floor sensor
Standard: 0
-2 ... +2 °C
Standard: 0 °C
0 ... 30 sec.
in 5 second incre-
ments
Standard: 15 sec.
DEU
ENG
ENG
FRA
NDL
ITA
ESP