Controller For The Air Source Heat Pump Water Heater
During this period, the following operations can be performed:
1) Press ▲ or ▼ to start or cancel the STERILIZE function. If this function is
started, the STERILIZE icon is displayed without blinking. Sterilization will be performed
circularly by the preset d and h value; If this function is canceled, the STERILIZE icon is
not displayed. If no operation is performed within 5 seconds, it will be regarded that this
function is not required. After this function is started and when sterilization is being
performed, the function icon blinks.
2) Press the TIMER button to enter the sterilization parameter setting interface.
Press ▲ or ▼ to select the d value and then press the TIMER button to confirm the
value. When the confirmed d value is not 0, the h value setting interface is displayed.
Press ▲ or ▼ to select the h value and then press the TIMER button to confirm the
value. When the STERILIZE icon is displayed, the STERILIZE function is started. If the
STERILIZE icon blinks, the preset h value (time point for sterilization) is achieved and
sterilization is being performed.
Sterilization
Parameter
d value
h value
Circular sterilization:
Meaning
Day interval for
circular sterilization
Time point for
circular sterilization
0-10 days; 0 indicates sterilization for
once only and the sterilization function
will be canceled after being performed.
00:00-23:00
12
Range