PEDESTAL FIXING Fig.1
The filter pump must be vertically fixed on ground or a certain
pedestal made of wood or concrete before use. There should
be two holes 7mm in diameter on the pedestal, the space
between which should be 256mm. Put filter pump on the
pedestal and fix them together by fasten the bolts and nuts. All
the pedestal parts should weigh over 18kgs at least to prevent
the pump from accidental falling.
Operation
1) Open/unscrew the Air Purge Valve on the top of the Filter Pump; air is released as water fills the Filter Pump.
2) When water comes out of the Air Purge Valve, screw it closed and wipe away any water.
3) To start the Filter Pump, insert the plug into a residual current device (RCD).
4) Turn on the switch to the "I" position.
RCD Test
A. Insert the plug into the power outlet.
B. Press the "RESET" button; the indicator light turns red.
NOTE: If the indicator light is not on, the test has failed.
C. Press the "T" button; the indicator light turns off.
NOTE: If the indicator light is not off, the test has failed.
D. Press the "RESET" button, the indicator light turns red.
E. Unplug the pump, and the pump is ready for use.
WARNING: RISK OF ELECTRIC SHOCK. The RCD plug must
be tested before each use.
WARNING: Do not use the pump if this test fails. Please contact
your local Bestway Customer Service.
WARNING: Insert the RCD plug into a residual current device (RCD)
having a rated residual operating current not exceeding 30mA.