Electrical connection (fig. 1)
Before connecting the device to the mains make sure that:
- the voltage and frequency rated on the data plate conform to those of the mains supply;
- an all pole circuit breaker which leaves at least 3 mm between the contacts has been installed
between the device and the mains;
- the wires are fastened down using a cable clamp.
Attention!
- a 6,3A fuse (not supplied with the product) must be wired in series with the 230V power supply.
- only low voltage circuits may be wired to the external circuit binding posts 7...9.
1-2
Power supply 230Vac 50-60Hz
3
Power supply earth connection
4
Motor output (phase 1)
5
Motor output (neutral)
6
Motor output (phase 2)
7
T1 (N.O.) input
8
Common
9
T2 (N.O.) input
L1
Indicator led