Starting the Heater: (Ignition)
1. Fill the tank with kerosene or other approved fuel
until needle on fuel gauge points to "F".
2. Replace fuel cap and tighten firmly.
3. Connect the heater to a three prong (grounded)
power source. You must use a three prong
(grounded) extension cord that is at least 6 feet
long and is a minimum of 14 AWG rating.
4. Press the power button to power on the heater
(see Figure 3).
5. Select desired temperature using temperature +/-
buttons.
6. The heater will ignite once the temperature setting
is higher than the ambient temperature in the
space.
Stopping / Restarting Heater:
-
To stop the heater, move the power switch to the
"Off" position and unplug the power cord.
-
To restart the heater; wait 10 seconds and follow
ignition steps.
Adjusting the Pump Pressure:
-
Remove the right side cover (4 screws). Behind the
panel, the pump will have a Phillips screw. There
is a small "P" next to the pump adjustment screw.
Turn screw in quarter turn increments.
-
Clockwise increases the pressure.
-
Counterclockwise decreases pressure.
© 2019 Pinnacle Climate Technologies, Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING
®
OPERATION (CONT.)
SDR 220 Rating Label + Control Panel
OR WHILE CONNECTED TO A POWER SOURCE
Model - Modelo
BTU/Hr - BTU/h
Fuel Consumption Gal./Hr.
Consumo de Combustible Gal./h
Fuel Tank Capacity Gal.
Capacidad del Depósito Gal.
Pump Pressure PSI - Presión de le Bomba
V~Hz/Amps - V~Hz/Amperes
TIP: If the heater does not ignite, the thermostat
Fuse - Fusible
Phase - Fase
may be set too low. Increase the temperature to a
Type of Fuel
Tipo de aceite combustible
higher setting until the heater ignites.
Maximum Air Outlet Temp. °F
Max. Temp. Del Aire De Salida °C
Minimum Distance From Combustibles:
Outlet: 8 ft. (250 cm) Sides / Top / Rear: 4 ft. (125 cm)
Minimas Distancias de Separacion de Materiales
TIP: If the heater does not ignite; press power
Combustibles:
Salida de Aire: 8 ft. (250 cm)
button to power off the heater, check steps 1-3
Lateral / Superior / Posterior: 4 ft. (125 cm)
See Operating Instructions and Troubleshooting on
above and press power button to power ON the
Las instrucciones de Funcionamiento y soluciónes
heater.
de problemas se encuentran en el panel lateral.
© 2018 Pinnacle Climate Technologies, Inc.
www.masterindustrialproducts.com
°F
Figure 3
7
Silent Drive Forced Air Heater User's Manual
MH-220T-SDR
220,000
1.67
13
123
120V~60Hz / 3.15
3.15A
No. 1 / Kerosene
No. 1 / Queroseno
1025
552
side panel.
COMPLIES WITH UL 733 AND
CAN/CSA-B140.0-03 AND CSA B140.8-1967
Made In China