4) Only after this check, carry out the final welding of
the S bracket. The actuator should be perfectly flat.
Important: the respect of dimensions indicated in Fig. 3
ensures the optimal operation of the automatic system.
These different dimensions may cause malfunctions.
In any case, the manufacturer shall be held
unharmed with respect to damages caused by the
non-respect of the dimensions indicated.
If it is not possible to carry out welding, adjustable
brackets, which can be mounted by using screws (art
B.SR), are available as optional accessory.
Fix the actuator to the bracket by means of screws and
nuts supplied. Use washers as shown in Fig. 4.
Note: The difference between measures X and Y shall
be never exceed 40mm. Greater differences cause the
unsmooth movement of the gate.
Dimensions M and X should be carefully checked to
avert that the actuator hits the pillar (dim. M) or the
leaf (dim. Z).
The total stroke of the actuator is around 320mm. The
stroke, however, cannot be entirely used. An extra
stroke of around 10 mm should be always provided
both in the closing and opening phases.
* In the BILL 30 geared motor, the difference in height
of brackets P and S shall be nil. These brackets should
be therefore fitted at the same height (Fig. 1, ref. A}
Wire connections
BILL 30 is supplied with a pre-cabled wire, around 80
cm long, to be connected to the junction box fitted to
the pillar.
BILL 30:
In the 230V model, the cable includes 4 terminals:
BLACK
Gear 1
BROWN
Gear 2
GREY
Motor, common
Yellow/Green Earth
BILL 3024:
In the 24V model, the cable includes 2 terminals (BLUE/
BROWN)

TECHNICAL DATA

Motor power supply
Consumption
Max. thrust
Operating jogging
Protection level
Operating temperature
Capacitor
Useful stroke
Noise
Lubrication
Weight
10
Note:
The motor cable shall be replaced only by an authorised
assistance centre.
IT IS MANDATORY to connect the system to ground
by using the special GND terminal, as provided by
regulations in force.
The insurance policy, which covers any damages or
injuries caused by manufacture faults, requires that
the installation comply with regulations in force and
Benincà original accessories be used.
BILL 30M
BILL 30MA
230Vac
115 Vac
50/60Hz
50/60Hz
1,35 A
2,7 A
3200 N
3200 N
30 %
30 %
IP54
-20°C / +50°C
10 μF
36 μF
300 mm
<70 dB
Permanent grease
6,5 kg
6,5 kg
WARNING
BILL 3024
24Vdc
5 A
2000 N
Heavy duty
-
4,9 kg