Electrical Requirements; Product Dimensions - Whirlpool KWVU205 Instructions D'installation Et Guide D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Electrical requirements

Important: Observe all governing
codes and ordinances.
It is the customer's responsibility:
• To contact a qualified electrical
installer.
• To assure that the electrical
installation is adequate and in
conformance with National
Electrical Code, ANSI/NFPA 70
— latest edition*, or CSA
Standards C22.1-94, Canadian
Electrical Code, Part 1 and
C22.2 No. 0-M91 - latest
edition** and all local codes
and ordinances.
If codes permit and a separate
ground wire is used, it is
recommended that a qualified
electrician determine that the
ground path is adequate.
Do not ground to a gas pipe.

Product dimensions

FRONT OF
VENT HOOD
9-1/2"
(24.1 cm)
glass shelf
extends
7" (17.8 cm)
1"
(25.4 mm)
9-1/8"
(23.2 cm)
11"
(27.9 cm)
Check with a qualified electrician
if you are not sure downdraft
vent is properly grounded.
Do not have a fuse in the neutral
or ground circuit.
IMPORTANT:
Save Installation instructions for
electrical inspector's use.
A.
A 120-volt, 60-Hz, AC-only,
15-ampere fused electrical supply
is required. A time-delay fuse or
circuit breaker is recommended.
It is recommended that a
separate circuit serving only this
appliance be provided.
B.
THE VENT HOOD MUST BE
CONNECTED WITH COPPER WIRE
ONLY.
30" (76.2 cm) model: 26" (66.0 cm)
36" (91.4 cm) model: 32" (81.3 cm)
(25.4 cm)
2-3/8"
(6.0 cm)
2"
(5.1 cm)
8"
(20.3 cm)
1-5/8"
(31.8 mm)
(41.3 mm)
5/8" to 2-1/8"
(1.6 cm to 5.4 cm)
1-7/16"
(3.6 cm)
30" (76.2 cm) model: 8" (20.3 cm)
36" (91.4 cm) model: 11" (27.9 cm)
10"
1/4"
(6.4 mm)
1-1/4"
2"
(5.1 cm)
C.
Wire sizes and connections
must conform to the
requirements of the National
Electrical Code, ANSI/NFPA 70 —
latest edition*, or CSA Standards
C22.1-94, Canadian Electrical
Code, Part 1 and C22.2 No. 0-M91
- latest edition** and all local
codes and ordinances.
D.
A U.L.- or C.S.A.-listed, 1/2"
(12.7 mm) conduit connector
must be provided at each end of
the power supply cable (at the
cooktop and at the junction box).
Copies of the standards listed may be obtained from:
* National Fire Protection Association
Batterymarch Park
Quincy, Massachusetts 02269
** CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
4-3/8"
(11.1 cm)
30" (76.2 cm) model: 13" (33.0 cm)
36" (91.4 cm) model: 16" (40.6 cm)
BACK OF
VENT HOOD
30" (76.2 cm) model: 29-7/8" (75.9 cm)
36" (91.4 cm) model: 35-7/8" (91.1 cm)
66" (167.6 cm) maximum distance from upper
cabinet hood mounting surface to floor
24" (61 cm) minimum distance from underside
of range hood to cooking surface or countertop
15" (38.1 cm) minimum upper cabinet height
13" (33 cm) upper cabinet depth
3-1/4" (8.3 cm)
3/8" (9.5 mm)
3

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Ykwvu205Kwvu265Ykwvu265Gz7730Ygz7730Gz7736 ... Afficher tout

Table des Matières