51300002101 RevA
CERTIFICATION CODES AND STANDARDS
DESIGN CERTIFIED
DESIGN COMPLIANT
INSTALLATION COMPLIANT ELECTRIC
CONFORMANCE WITH CODES: The heater shall be installed in accordance with all local and state codes and with
the requirements of the authority having jurisdiction of the installing site. The heater installation must conform to the
latest edition of the above listed installation codes.
SAFETY INFORMATION
WARNING
Failure to follow instructions can cause death, severe injury and/or serious property damage.
WARNING
damaged, broken, cracked, missing, or unsecured can cause death and/or severe injury due to the following
entrapment hazards:
Hair Entrapment- Hair can become entangled in suction outlet cover.
Limb Entrapment- A limb inserted into an opening of a suction outlet sump or suction outlet cover that is damaged,
broken, cracked, missing, or not securely attached can result in a mechanical bind or swelling of the limb.
Body Suction Entrapment- A negative pressure applied to a large portion of the body or limbs can result in an
entrapment.
Evisceration/ Disembowelment - A negative pressure applied directly to the intestines through an unprotected
suction outlet sump or suction outlet cover which is, damaged, broken, cracked, missing, or unsecured can result
in evisceration/ disembowelment.
Mechanical Entrapment- There is potential for jewelry, swimsuit, hair decorations, finger, toe or knuckle to be caught
in an opening of a suction outlet cover resulting in mechanical entrapment.
WARNING
o
When outlets are small enough to be blocked by a person, a minimum of two functioning suction outlets per pump
must be installed. Suction outlets in the same plane (i.e. floor or wall), must be installed a minimum of three feet
(3') [1 meter] apart, as measured from near point to near point.
Dual suction fittings shall be placed in such locations and distances to avoid "dual blockage" by a user.
o
o
Dual suction fittings shall not be located on seating areas or on the backrest for such seating areas.
o
The maximum system flow rate shall not exceed the flow rating of as listed on Table 1.
o
Never use Pool or Spa if any suction outlet component is damaged, broken, cracked, missing, or not attached.
o
Replace damaged, broken, cracked, missing, or not securely attached suction outlet components immediately.
o
In addition two or more suction outlets per pump installed in accordance with latest ASME, APSP Standards and
CPSC guidelines, follow all National, State, and Local codes applicable.
o
Installation of a vacuum release or vent system, which relieves entrapping suction, is recommended.
–
WARNING
Failure to remove pressure test plugs and/or plugs used in winterization of the pool/spa from the
suction outlets can result in an increase potential for suction entrapment as described above.
WARNING
–
Failure to keep suction outlet components clear of debris, such as leaves, dirt, hair, paper and other
material can result in an increase potential for suction entrapment as described above.
WARNING
–
Suction outlet components have a finite life, the cover/grate should be inspected frequently and
replaced at least every seven years or if found to be damaged, broken, cracked, missing, or not securely attached.
CAUTION
–
Components such as the filtration system, pumps and heater must be positioned so as to prevent their
being used as means of access to the pool by young children. To reduce risk of injury, do not permit children to use or
climb on this product. Closely supervise children at all times. Components such as the filtration system, pumps, and heaters
must be positioned to prevent children from using them as a means of access to the pool.
WARNING
hazardous pressure during start up, normal operation, and after pump shut off. Stand clear of circulation system
equipment during pump start up. Failure to follow safety and operation instructions could result in violent
separation of the pump housing and cover, and/or filter housing and clamp due to pressure in the system, which
could cause death, severe personal injury and/or property damage, Before servicing pool and spa water
circulation system, all system and pump controls must be in off position and filter manual air relief valve must be
in open position. Before starting system pump, all system valves must be set in a position to allow system water
to return back to the pool. Do not change filter control valve position while system pump is running. Before
starting system pump, fully open filter manual air relief valve. Do not close filter manual air relief valve until a
steady stream of water (not air or air and water) is discharged.
6
Table2: CERTIFICATION AND COMPLIANCE
–
Read, Understand, and Follow all Instructions in this manual and on the equipment.
–
Suction Entrapment Hazard. Suction in suction outlets and/or suction outlet covers which are,
-
To Reduce the risk of Entrapment Hazards:
–
Hazardous Pressure. Pool and spa water heating and circulation systems operate under
USE ONLY GENUINE REPLACEMENT PARTS
USA
ETL/ITS
UL60335-1&2
ANSI/NFPA 70
NEC
CANADA
ETL/ITS
CSA C22.2 No.60335-1&2
CSA C22.1 – Canadian
Electrical Code, Part I