Electrical Specifications - MasterCraft 62-3558-8 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation

ELECTRICAL SPECIFICATIONS

Motor
Motor
Full Load
H.P.
Amps
1/6
1.5
PUMP CAPACITY
Head in feet
0
Head in metres
0
Litres/minute
76
Gallons/minute
20
INSTALLATION
See Fig. 1 for typical installation connections to pump
(NOTE: Fountain accessories not included with pump).
GFCI
outlet
Power
cord
Landscaping
rocks
Figure 1: Typical garden pond and waterfall installation.
Minimum
Pumps
Circuit
Down
Req. (Amps)
To
15
7/16" (11 mm)
5
10
15
20
1.5
3
4.5
6.1
63
43
25
17
11
7
Use foliage to cover
tubing to waterfall
Plastic
tubing
to waterfall
Diverter
valve
3388 0399
Raise the pump
off of the bottom
of the pond
CUSTOMER HOTLINE: 1-877-455-5508
1. Install the pump on a hard level surface. Make sure
that the pump cannot pick up rocks, mud and debris,
etc. If necessary, put a block under the pump to raise
it slightly. If used with a fountain jet, position the
pump so that the fountain jet is above the surface of
the water.
2. Protect the power cord from damage. Uncovered
cords should be routinely inspected for damage or
deterioration. DO NOT operate the pump if the cord
is damaged.
3. If used in a garden pond, adjust the diverter valve to
control the fountain spray height and flow over the
waterfall. Do not restrict pump suction to adjust
0
flows. Restricting the suction will starve the pump for
0
water and can damage the pump.
4. If the pump is connected to a pond filter, adjust the
diverter valve to provide adequate flow to the filter.
Refer to the filter instruction manual to determine
flow requirements of filter.
Pump includes the adaptors below.
1/2, 3/4, or
1", barbed
hose adaptor
1 1/4 x 1" NPT
adaptor
1" NPT to
garden hose
adaptor
Figure 2: Typical installation setup.
3
Includes
three
different
adaptors

Publicité