INSTALLATION MANUAL
INTBUSW
Wiegand door controller
150mA max.
Without jumper : without clock
With jumper : with clock
STAND ALONE MODE
TELACCESS
- Dipswitch address set up
- Dip4 = ON
DIP SWITCH adressing
1
2
3
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
OFF
ST1 (Programming jumper)* : Normal
* The readers must be installed one at a time (can not program the readers at the same time).
INTBUSW (Reader controller)
Terminal block : Motherboard
V
Output Voltage - (To reader)
12
Output voltage + (To reader)
1
D0 - Data O (From reader)
2
Clock (From reader)
3
D1 - Data 1 (from reader)
Terminal block : Motherboard
R
N/C contact - Fail safe lock (+) - Relay 1
C
Common contact power supply (+) - Relay 1
T
N/O contact - Fail secure lock - Relay 1
R
N/C contact alarm - Relay 2
C
Common - Relay 2
T
N/O contact alarm - Relay 2
+ ~ - Input voltage 12V ac/dc or 24V dc
P1
Request-to-enter input
M
Common ( P1 et P2 )
P2
Request-to-enter input
E
Door position contact, N/C (Door closed) and N/O (Door open)
L
Reader activation input (N/O) reader enabled and (N/C) reader disabled
M
Common ( E and M ) or (E and L)
A
RS485 Bus (All the A must be connected together in daisy chain)
B
RS485 Bus (All the B must be connected together in daisy chain)
Terminal block - 3 points : Piggyback board
7
Buzzer
8
LED > Green color
9
LED > Red color
4
Mode
ON
Front plate
ON
Reader 1
ON
Reader 2
ON
Reader 3
ON
Reader 4
CENTRALIZED MODE
- TERENA,
- UGM-UGL,
- UGP/40
- PDN345BUSPROX
- Address programming during installation
- Dip4 = OFF
ST1 (Programming jumper)*
Normal (As standard)
EN
Installation
cdvi.com
5
cdvigroup.com