Preparation
If codes permit and a separate ground wire is used, it is recommended that a
qualified electrical installer determine that the ground path and the wire gauge are
in accordance with local codes.
Check with a qualified electrical installer if you are not sure the oven is properly
grounded.
This oven must be connected to a grounded-metal permanent wiring system.
Be sure that the electrical connection and wire size are adequate and in
conformance with the National Electrical Code, ANSI/NFPA 70-latest edition or CSA
Standards C22.
1-94, Canadian Electrical Code, Part 1 and C22.2 No. O-M91-latest edition, and all
local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
8 English
Install_NW9000K-DG68-00862A-02_EN+MES+CFR.indb 8
Electrical Connection
To properly install your oven, you must determine the type of electrical connection
you will be using and follow the instructions provided in this manual.
Oven must be connected to the proper electrical voltage and frequency as
specified on the model/serial/rating plate. The model/serial/rating plate is
located below the control panel on single ovens and double ovens. See the
following illustrations.
A
Single Oven
A. Model/serial/rating plate
A circuit breaker is recommended.
Use the chart below to determine the minimum recommended dedicated
circuit protection.
KW Rating (240 V)
KW Rating (208 V)
≤4.8 KW
4.9 KW - 7.5 KW
4.3 KW - 6.2 KW
7.3 KW - 9.6 KW
6.3 KW - 8.3 KW
9.7 KW - 12.0 KW
8.4 KW - 10.4 KW
Connect directly to the circuit breaker box (or fused disconnect) through
flexible, armored or nonmetallic sheathed, copper cable (with grounding wire).
See "Electrical Connection" section.
A
Double Oven
A. Model/serial/rating plate
Recommended Circuit
Size (Dedicated)
≤4.1 KW
20 Amp
30 Amp
40 Amp
50 Amp