3. CONNECTIONS
CONNECTION AND POWER DAISY CHAIN
AUTO-RANGE
MAINS INPUT
220-240V~ 50-60Hz 1,6A
100-120V~ 50-60Hz 2,7A
The figure above shows a general connection where a module 1
is over module 2. For this purpose, use cables with powerCON TRUE1® connectors (not provided).
•
Connect the power supply of module 1 AUTO-RANGE MAINS INPUT (A).
•
Link the power supply from module 1 to module 2 connecting the output MAINS LINK (B) of module
1 to the input AUTO-RANGE MAINS INPUT (C) of module 2.
•
Repeat this procedure until connecting the maximum permitted number of the line-array module
(refer to section SPECIFICATIONS).
WARNING
•
VIO-X206
MAINS LINK
220-240V~ 14,4Amax
3310Wmax
100-120V~ 17,3Amax
1900Wmax
MODULO 1
!
The cables must be properly sized and the system's design, installation and
testing should be performed by qualified personnel only. AEB industriale declines
any responsibility in case of cables that are non-compliant, uncertified and
incompatible with the proper layout of the system and the regulations in force
for the country of use.
AUTO-RANGE
MAINS LINK
MAINS INPUT
220-240V~ 14,4Amax
220-240V~ 50-60Hz 1,6A
100-120V~ 50-60Hz 2,7A
3310Wmax
100-120V~ 17,3Amax
1900Wmax
MODULO 2