Continuous Or Extended Operation; Transport; Cleaning And Maintenance; Cleaning The Air Filter - ATIKA LT 500 Notice Originale

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 23
4.
Re-insert the container. When inserting put
the draining hose (3) into the water collecting container.
Make sure that the container is correctly positioned.
5. Close the hinged enclosure cover.
6. Restart the air dehumidifier. The
E4 should no longer be displayed.
Icon and fault code are further displayed? Remove the
container again and re-insert it properly.

Continuous or extended operation

In the case of a high humidity of air it is recommended to
operate the air dehumidifier in continuous mode. In continuous
mode it is not needed to empty the water collecting container.
 LT 500:
Proceed as follows:
1. Remove the water collecting container from the device.
2.
Remove the stopper (9).
3. Re-insert the collecting container in the device.
4.
Guide the hose (14) through the housing.
Push the hose on the water drain nozzle (a).
 LT 800:
Proceed as follows:
1. Remove the water collecting container from the device.
2.
Put the draining hose (3) through the hole
in the enclosure and pull it out of the device on the other
side
.
3. Re-insert the collecting container in the device.
4. Close the hinged enclosure cover.
5. Place a large collecting container below the water draining.
Or:
Extend the water draining using a garden hose to pipe the water
into a drain channel.
Pay attention to the following:
Make sure that the water can flow out unhindered.
Pipe the water preferably to a drain which is positioned at
a lower level.
Make sure that the hose remains in its position, is routed
with a descending gradient, is not kinked or wound up.
T
r
T
Power off the device and disconnect the mains
plug before each transport.
Always transport the air dehumidifier in upright (vertical) position
to prevent compressor damages.
Hint: If you have transported the air dehumidifier in
another than upright position (horizontal or tilted),
allow the air dehumidifier to stand in upright position
for at least one hour before starting it up.
18
icon and the fault code
a
n
s
p
o
r
t
r
a
n
s
p
o
r
t
C
l
e
a
n
i
n
g
a
C
l
e
a
n
i
n
g
a
Turn off the device and disconnect the power
plug before each cleaning and maintenance
work.
Maintenance and repair work other than those described in this
chapter is only allowed to be carried out by service staff.
Only use genuine spare parts. Other than genuine parts may
result in unpredictable damages and injury.
Cleaning air filter
A contaminated filter
deteriorates the performance of the air dehumidifier,
results to contamination inside the device.
Clean the filter in regular intervals depending on the
operating conditions.

Removing the filter

 LT 500:
1. Open the enclosure door.
2.
Remove the filter (10).
 LT 800:
1.
Remove the enclosure door (4).
2.
Pull out the three fixing bars (5)
the filter (6) from the enclosure door for cleaning
Slight contamination
Use a vacuum or slightly knock off the filter to clean it.
Bad contamination
Carefully wash the filter in luke-warm soapy solution (max.
40 °C) and then allow it to dry well. Do not expose the filter to
sunlight or other heat sources to dry it.

Inserting the filter

 LT 500:
1. After cleaning, reinsert the filter in the guides on the
enclosure door.
2. Close the enclosure door.
 LT 800:
1. Place the filter in the enclosure door and secure it using the
three fixing bars.
2. Re-mount the enclosure door.