INLET AIR
Before Installation
The air inlet vent should be installed as close to the Cinderella as
possible. This ensures good air supply to the toilet and reduces the
environmental impact in the toilet room. It is important that there are
no other air-dependent installations in the same room, e.g. extractor
fan or fireplace. The Cinderella Classic draws air mainly from the
underside of the toilet. It is therefore possible to have the air intake
underneath the toilet (fig. 8). This allows you to insulate the air as
much as possible in the toilet to minimize the environmental impact in
the toilet room.
Guidelines for The Inlet Air
•
The inlet vent's minimum dimensions must be 6
mm) diameter/31 in² (201 cm²). It is recommended to use the
included vent.
•
The vent must be open at all times. Remember to clean the vent
at regular intervals.
•
Make sure that there is no conflict between the toilet's air supply
and other installations, such as a fireplace or extractor fan (fig. 9).
•
Be aware that open windows may disturb the toilet's function.
•
Do not use a separate ventilation fan to extract air from the room
where the toilet is installed.
•
If you have open ventilation under the toilet, it may be advisable to
use a mosquito net over the hole to keep out insects and the like.
It is important that this mosquito net is not too fine-mesh so that
it creates too little air flow.
Protecting the Floor
If the T-piece is installed indoors, you must place a bowl
underneath to collect any condensation. Push the supplied
ventilator cowl into the pipe until it stops (fig. 10).
Fig. 10
10
5/16
in. (160
Adjustable Vent
The included vent has an adjustable opening, but should
always be positioned at level 2, approximately 2 in. (50mm)
or more (fig. 11). If an adjustable vent is already installed in
the room, it must always be open, with nothing hindering the
air flow in the vent.
2 in.
(50mm)
Fig. 11
fig. 8
fig. 9
OPEN
24|7