All safety instructions in this manual are marked with this symbol. Please be sure to pay close
attention to all instructions given in this manual, especially when you see this symbol.
IMPORTANT NOTE:
Read this entire installation manual prior to installation. The homeowner should keep this installation
manual for future references. Visit www.cinderellaeco.com for detailed step-by-step animations for the installation of your new
toilet. It can be a good idea to look at these animations prior to installing your new Cinderella Classic toilet. They can be a useful
tool in addition to this manual.
Electrical Specifications and Requirements
IMPORTANT NOTE:
Extension cords should not be used with this appliance.
IMPORTANT NOTE:
This appliance must be installed in accordance with National Electrical Codes, as well as all state,
municipal and local codes. The correct voltage, frequency and amperage must be supplied to the appliance from a dedicated,
grounded circuit which is protected by a properly sized circuit breaker. The proper voltage, frequency and amperage are listed
in this manual, and on the product rating plate on the back of the toilet.
The toilet is delivered with a 15 amp NEMA 6-15 plug and chord (fig. 1). To supply sufficient power to the unit as delivered, it
will require a Nema 6-15R receptacle on a dedicated grounded circuit, with at least 10 amps of available power at 220 V AC.
If you do not have the appropriate receptacle available, please contact a licensed electrician to assist with your installation.
•
Power Supply
•
Current
•
Power Consumption
IMPORTANT NOTE:
Cinderella Classic has a power consumption level of approxi-
mately 2000W while incinerating, which may be sustained over periods exceeding
an hour at a time. Make sure that your electrician takes this electrical load into
consideration.
POWER CONVERTERS: Power converters are not recommended for use with your
Cinderella product. Cinderella Classic has a maximum power consumption level of
2000W, which may be sustained over periods exceeding an hour at a time. Power
converters with a "peak consumption" level of 2000W may be unable to maintain
this power output and become overloaded, damaged or unsafe if used with your
Cinderella Classic..
BATTERIES, GENERATORS and SOLAR PANELS are not sufficient as a power source
for Cinderella Classic.
Environmental Requirements
Ambient temperature range: -5–105°F (-20–40°C)
•
Operating altitude: Tested to 8,200 feet (2500 m)
Warning: Before cutting any holes, always check that you will not hit any electrical wiring or water
follow safety precautions may cause serious injury or death
4
240/220 V AC, 60 Hz
10 amp
2000W
fig. 1
15 AMPERE-250 VOLT
(NEMA 6-15P) PLUG
pipes.
Failure to