Error message
WARNING
NO WATER
WARNING
MOTOR BLOCKED
WARNING
HIGH TEMPERATURE
WARNING
HIGH POWER
Storage/Over-wintering
The unit is frost-proof to -20 °C. If lower temperatures are expected, the unit must be removed and put into storage.
How to correctly store the unit:
• Protect the DMX/RDM connectors from moisture and dirt.
Wear parts
The following components are wear parts and are excluded from the warranty:
• DMX plug seal
Disposal
Do not dispose of this unit with domestic waste! For disposal purposes, please use the return system provided.
Disable the unit beforehand by cutting off the cables.
12
Cause
The pump has run dry (dry run protection has tripped).
Filter housing clogged (dry run protection has tripped).
Impeller unit is blocked (dry run protection has tripped).
Ambient temperature for dry installation is too high.
Water temperature too high
Current consumption too high
– Impeller unit running sluggishly
– Excessively soiled water
Remedy
– Flood the pump.
– Fully submerge the pump for operation in a pond.
– Vent the supply line.
– Remove any blockage from the supply line.
Clean the pump.
Disconnect the power supply and remove obstacle. Then
switch the pump on again.
– Avoid exposure to direct sunlight.
– Note maximum water temperature of +35°C.
Note maximum water temperature of +35°C.
Clean the pump.