Honeywell VisionPRO IAQ Guide D'installation page 5

Masquer les pouces Voir aussi pour VisionPRO IAQ:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installer setup
Setup function
0404
Max. ventilation
% limit
0405
Ventilation fan
action
0406
Ventilation in high
humidity
0430
Ventilation lockout
0431
Ventilation lockout
high temperature
0432
Ventilation lockout
low temperature
0450
DATS Inhibit
0500
Furnace filter
change alert
0502
Furnace filter
alert options
0510
Humidifier pad
change alert
0520
UV lamp change
alert
0530
Adaptive Intelligent
Recovery™
0540
Program periods
0580
Compressor off
time (min.)
0600
Heat temperature
range stop
0610
Cool temperature
range stop
0640
Clock format
* Humidifier Pad replacement will be displayed in the user interface as run
time days if ISU 372 is set to 1 or 3 and calendar days if ISU 372 is set to 0.
Settings & options (factory default in bold)
50
50% ventilation limit
[Other options: 30% to 60% or 100%]
P
Meets ASHRAE 62.2 standard
F
Does not meet ASHRAE 62.2 standard
1
Ventilation on forces fan on
2
Ventilation does not force fan on
1
On (heat mode only)
0
Off
0
Disabled
1
Lockout for high temperatures
2
Lockout for low temperatures
3
Lockout for high and low temperatures
100 100°F (38°C): Settings 5°F apart (3°C)
[Other options: (90°F to 110°F/32°C to 43.5°C)]
-10 -10°F (-23.5°C): Settings 5°F apart (3°C)
[Other options: (-20°F to 0°F/-29°C to -18°C)]
0
Disabled: Settings 5°F apart (3°C)
[Other options: (35°F to 65°F/1.5°C to 18.5°C)]
E
Auto Discover
0
Off
1
10-day run time
2
30-day run time
3
60-day run time
4
90-day run time
5
120-day run time
6
180-day run time
0
Timer counts Heat & Cool run time
1
Timer counts Cool run time only
E
Auto Discover
*
0
Off
1
90 calendar days or 30 days run time
2
180 calendar days or 60 days run time
3
365 calendar days or 90 days run time
E
Auto Discover
0
Off
1
365 calendar days (1 year)
2
730 calendar days (2 years)
1
On
**
0
Off
4
4 program periods (Wake, Leave, Return, Sleep)
2
2 program periods (Wake, Sleep)
5
5 minute compressor off time
[Other options: 0 to 4 minutes]
90
Max. heat temperature setting is 90°F (32°C)
[Other options: 40 to 90°F (4°C to 32°C)]
60
Min. cool temperature setting is 60°F (15°C)
[Other options: 60-99°F (15°C to 37°C)]
12
12-hour time (i.e., "3:30 pm")
24
24-hour time (i.e., "15:30")
**
**
**
7
270-day run time
8
365-day run time
9
30 calendar days
10
60 calendar days
11
90 calendar days
12
120 calendar days
13
180 calendar days
14
365 calendar days
**
**
**
5
VisionPRO
**
**See pages 6 & 7
69-1816EFS—07
IAQ
®

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Visionpro iaq thm5421c

Table des Matières