Honeywell VisionPRO IAQ Guide D'installation page 2

Masquer les pouces Voir aussi pour VisionPRO IAQ:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation Guide
Installer setup
1 Press SYSTEM
TUE
FAN
70
Inside
AUTO
SYSTEM
HEAT
6:00
aM
SCHED
HOLD
Installer setup
Setup function
0110
Zone number
0120
Year
(first two digits)
0130
Year
(second two digits)
0140
Month
0150
Date
0160
Schedule format
0165
Restore Energy
Star schedule
0172
System type
0173
Heat Pump Type
0174
Cooling compressor
stages
0176
Heat or Heat Pump
Aux stages
0180
Fan control
(conventional heat)
0190
Changeover valve
(O/B terminal)
0200
Backup heat
(Aux & EmHeat)
69-1816EFS—07
TUE
2 Press and hold for 5 seconds
3 Change settings (see p. 2-6)
SYSTEM
HEAT
6:00
aM
TUE
70
Inside
DONE
Function
6
0120
DONE
Press s t to change
Settings & options (factory default in bold)
0
Not zoned
1–9 Zone number
20
(2000-2099)
21
(2100-2178)
06
(2006)
[Other options: 00-99]
6
[Other options: 1-12]
15
[Other options: 1-31]
4
7-day programming
0
Non-programmable
0
No
1
Yes
1
Conventional
2
Heat pump
3
Heat only (no fan)
E
Auto Discover
0
Air to Air heat pump
1
Geothermal heat pump
1
1 stage of cool
[Other options: 0 or 2 stages, or E]
1
1 stage of heat
[Other options: 0, 2 or 3 stages, or E]
0
Gas/Oil heat (equipment controls heating fan)
1
Electric furnace (thermostat controls heating fan)
2
Equipment controls stage 1, thermostat controls stage 2+
E
Auto Discover
0
O/B terminal controls valve in cooling
1
O/B terminal controls valve in heating
E
Auto Discover
0
Electric backup heat
1
Fossil fuel backup heat
CANCEL
Setting
20
**
**
**
2
TUE
70
Inside
Press DONE to save & exit
0120
DONE
20
**See page 6