Battery Charge Level Gauge - TSM ARIA 240 Instructions Originales

Aspirateur déchets urbains
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

ARIA 240 & 240 SUPER
OPERATING MANUAL
2. Remove the outer packing lifting. The machine is fastened to its platform by wedges that clamp its wheels and with a
polyethylene blade;
3. Remove the stopper holding the steering handle in the storage position;
4. Use the ramp that you will find in tha packaging to lower the machine off the platform, pushing it in reverse;
5. Keep the platform since it may be necessary to transport the machine again.
8.3 Putting the batteries in the machine
The batteries must be housed in the battery compartment below the solution tank and must be handled using special
hoisting equipment suitable both for the weight and for the hooking system.
Strictly comply with the instructions given by the battery manufacturer or retailer regarding battery
maintenance and daily recharging. All installation and maintenance procedures must be carried out by
specialists.All the recharging operations must be carried in well-aired places, far from heat sources. Do not
smoke, do not bring free flames near, do not use emery wheels and welding, do not cause sparks near
batteries. Do not withdrawal current from batteries with pliers, sockets and provisional contacts. Make sure all
connections (cable lugs, sockets, plugs, etc.) are always tight and in good conditions.
When you manipolate batteries always wear safety cloth according to the currently laws. In particular,
before manipulating batteries, take off all metallic objects such as rings, necklace and watches from
hands, wrists and neck. Do not lean metallic objects on the batteries.
When inserting the batteries:
1. Remove the right side panel;
2. Rotate the vacuum holder plate until full tilt;
3. Place the batteries according to the diagram and connect them with the data cables supplied. Avoid that tools come
into contact simultaneously with more than one pole of the battery (Fig. 1);
4. Return the vacuum holder palte to the original position;
5. Taking care to not damage cables, close the right side panel.
8.4 Connecting the battery connector
The electrical connection battery / machine is located under the console (the battery connector is mobile and it has a
handle, while the machine connector is fixed the frame).
During operation, the battery connector must remain connected to the machine; during the re-charge, the battery
connector must be attached to the charger.
Check the perfect connectors' coupling.
8.5 Recharge of batteries
In order not to cause the risk of permanent damage to the batteries, one should at all costs avoid their complete
discharge and effect recharging within a few minutes after that the signal lamp of discharged batteries begins to blink.
Never leave the batteries completely discharged, even if the machine is not being used. Do not leave one
battery to discharge separately from the other. Every 10 recharging operations check the level of the electrolyte
and, if necessary, top up with distilled water. Fill up each batterie cell only after charging. After the filling up
replace and screw the batteries caps.
When recharging the batteries, removed the side panels. Make sure that the battery charger fits the installed
batteries both for capacity as for type. Use ONLY TRACTION batteries OPEN/PURE LEAD/ACID or GEL.
Never charge a GEL battery with an unsuitable battery charger. Carefully follow the instructions given by the
manufacturer of batteries and battery charger.
Danger of gas exhalations and emission of corrosive liquids.
Fire danger: do not approach with free flames.

8.6 Battery charge level gauge

When the key is in position "1", the digital display (Nr. 3 of CONTROLS AND INSTRUMENTS) indicates:
1.
The charge level of the battery;
2.
The level of minimum expected voltage / acceptable to the batteries (adjustable in function of used batteries);
3.
Working hours.
The vacuum motors automatically turns off when the battery level is at minimum. The remaining charge can be
used to bring the machine to the recharging point.
V01
TSM - Technological Systems by Moro Srl
Via F.lli Zambon,9 - 33080 Fiume Veneto (PN) – Italy
Tel. +39.0434.564167 - Fax +39.0434.954069
www.tsmitaly.com – sales@tsmitaly.com