Master/Slave-Operation
The master/slave-operation enables that several devices can be synchronized and controlled by one master-
device.
On the rear panel of the EUROLITE LED Bar RGB 252/10 Indoor you can find an XLR-jack and an XLR-
plug, which can be used for connecting several devices.
Choose the device which is to control the effects. This device then works as master-device and controls all
other slave-devices, which are to be connected to the master-device via a stereo shielded cable. Connect
the OUT-jack with the IN-plug of the next device.
Set DIP Switch 10 to ON in order to determine the Slave device.
The Master device is now capable of controlling the Slave devices while in Stand Alone Mode.
Connection with the mains
Connect the device to the mains with the power-plug.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.
OPERATION
After you connected the spot to the mains, the EUROLITE LED Bar RGB 252/10 Indoor starts running. This
unit has two operating modes. It can be run as a Stand Alone-unit or DMX-controlled.
STAND ALONE OPERATION
In Stand Alone Mode you can use the LED Bar RGB 252/10 Indoor without a controller.
Control via Dip Switches
You can choose from the following operational modes: Internal Programs, Auto, Sound Control, Slave,
and DMX.
International
L
N
17/39
00026099.DOC, Version 2.3