Error codes / common problems
The welder 00E8500L has a number of safety systems to monitor welding and welding
parameter entry. Error codes are always displayed on the screen. To delete a displayed
error code, disconnect the fitting and press ESCAPE ESC when prompted.
For
any
additional
REPRESENTATIVE
Tel: +39 0331 344211 – Fax: +39 0331 351860
E-mail: info@nupinet.com
ERROR
ERROR TYPE
CODE
0
OK
AMBIENT
2
TEMPERATURE
OFF LIMITS
SHORT CIRCUIT/
4
OVERLOAD
5
OPEN CIRCUIT
6
ADJUSTMENT
MAX
INSIDE
12
TEMPERATURE
13
POWER FAILURE
22
MANUAL STOP
INPUT VOLTAGE
23
OFF LIMITS
101
RAM MEMORY
WELDING CABLE
102
BREAK
INTERNAL
103
TEMPERATURE
PROBE
information
please
contact
ERROR DESCRIPTION
During printing, it shows that welding has
been successfully completed.
Ambient temperature is either lower than
-10°C or higher than 45°C.
Current has exceeded limit
(partial fitting short-circuit or fitting made
by other manufacturers).
Fitting might be faulty or welding cables
not correctly connected to the fitting.
Extension cable out of tolerance range.
Polyvalent welder inside temperature
over 80°C.
A power failure has occurred during
welding.
ESC has been pressed during the
welding cycle.
Input voltage is higher or lower than the
rated operating voltage by 20%.
RAM memory data and date/time not
valid
Welding cable is damaged
Internal Temperature Probe failure
8
our
CUSTOMER
SERVICE
RECOMMENDED ACTION
No action required.
Check that the temperature reading on
the welding unit screen is consistent
with the actual room temperature.
Prevent direct exposure to sunlight. If
the room temperature read by the
welding unit is not correct, contact our
Customer Service Representative staff.
Replace fitting.
Check connection to the fitting.
Check connectors efficiency.
Check that extension diameter and
length are within the recommended
range of values.
Wait for the welding unit to cool down.
After restoring normal power input
parameters, wait for the fitting to cool
down completely before repeating the
welding procedure from the start.
Wait for the fitting to cool down
completely
welding procedure from the start.
Make sure that the power source or the
generator are operating efficiently.
Internal battery could be flat.
Re-enter
persists contact customer care
Do not weld and replace damaged part.
Contact our After-Sale Service staff.
before
repeating
date/time
and
if
problem
the