Common Operation - CDVI STAR1M Manuel D'installation

Masquer les pouces Voir aussi pour STAR1M:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION MANUAL
STAR1M - Mullion Mifare

7.3 Common operation

Program or replace a Master badge :
ON
ON
ON
ON
ON
OFF
1
2
3
4
Set DIP2 to OFF
Program the unlock time :
Default value : 5 seconds, programmable from 01 to 99 seconds
Enter in programming
Yellow LED
Present the master badge
Delete all cards (reset the reader to the factory
default values)
ON
ON
ON
ON
ON
OFF
1
2
3
4
Switch off power supply
Set DIP1 to ON
card reader
®
Yellow LED
+ Beep
Present the new master badge
(the old will be erased)
Beep + LED OFF
mode
Press the push button
Each push button press : 1 second
Switch on power
supply
White/Red LED flashing while the
memory is deleted.
Followed by start-up sequence
To delete all cards switch to wiegand mode
ON
ON
ON
ON
ON
OFF
1
2
3
4
Set DIP2 to ON
After 10 seconds
White and Red LED flashing
+ Beep
1 flash : 1 second
Switch off power
supply
Set DIP1 and DIP2 to OFF
Standalone Mode activated
Switch on power supply
Switch to standalone mode
EN
Beep
Blue LED
Blue LED
ON
ON
ON
ON
ON
OFF
1
2
3
4
17
cdvigroup.com

Publicité

Table des Matières
loading

Table des Matières