FRONT PANEL CONNECTION STATUS LIGHTS
PRIMARY LINK
PRIMARY LINK
START
START
SECONDARY LINK
SECONDARY LINK
SEQUENCE
SEQUENCE
PRIMARY LINK – Multi-color LED indicates communi-
cation status in regards to Secondary Link hierarchy:
GREEN
Unit is communicating through Secondary
Link to preceding unit's Primary Link OUT.
RED
Unit has lost continuity and cannot communi-
cate SmartSequencing hierarchy.
Please Note: A slow blinking GREEN PRIMARY
LINK LED indicates the unit is configured as the
MAIN Primary unit per DIP Switch 8. (Factory
default).
Please Note: A SECONDARY DEVICE should have
a solid green PRIMARY LINK LED.
REAR PANEL FEATURES
PHOENIX TYPE CONNECTORS
Remote Barrier Strip (1)
REMOTE PORT
SMARTSEQUENCING
OUT
+12V - Main DC terminal output for
remote triggering
P
+12V
STAT - DC terminal output for a
P
STAT
remote LED indicator (ANODE)
S
REM
REM - Main terminal input for remote
S
GND
triggering
IN
GND - Terminal for remote LED status
CLASS 2 WIRING
and/or triggering (CATHODE)
CN-1800S
120~V, 50/60/HZ
UNSWITCHED
15A MAX
UNSWITCHED
10 FT. AC
OUTLET BANK
POWER CORD
ALWAYS ON
CN-2400S 20A REAR PANEL OUTLETS. ALL OTHER REAR PANEL
FEATURES ARE COMMON FOR CN-1800S AND CN-2400S
DELAY 1
DELAY 1
DELAY 2
DELAY 2
ETHERNET
DELAY 3
ETHERNET
DELAY 3
SECONDARY LINK – Multi-color LED indicates
communication status in regards to Primary Link
hierarchy:
GREEN
Primary Link to following unit's Secondary Link IN.
OFF
Unit has lost continuity and cannot
communicate SmartSequencing hierarchy.
Please Note: An unlit SECONDARY LINK LED
indicates last unit in sequencing chain. A single
unit will have an unlit SECONDARY LINK LED
FORCE OFF
REMOTE PORT
SMARTSEQUENCING
OUT
FO
+12V
FO
STAT
COMM/
NO
POWER
REM
NC
GND
C
IN
DELAY 3
CLASS 2 WIRING
Rear LED – Indicates unit is receiving AC power and "Unswitched" outlets are active.
DELAY 1
DELAY 1
OUTLET
BANK
www.furmancontractor.com
1
2
3
4
5
1
2
3
4
5
POWER
N.O.
12V ON
PRIMARY LINK
POWER
1M
1M
2M
2M
4M
4M
N.O.
12V ON
PRIMARY LINK
START
START
N.C.
12V OFF
N.C.
12V OFF
DLY
DLY
PROTECTION OK
SECONDARY LINK
PROTECTION OK
SECONDARY LINK
ADJ
ADJ
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
GND
GND
MOM
MOM
PRI
PRI
EVS AUTO
EVS AUTO
EXTREME VOLTAGE
ETHERNET
EXTREME VOLTAGE
SEQUENCE
ETHERNET
SEQUENCE
ON
ON
MNT
MNT
SEC
SEC
MANUAL
MANUAL
6
7
8
9
6
7
8
9
Unit is communicating through
SmartSequencing Barrier Strip (2)
REMOTE PORT
FORCE OFF
Primary poles connect OUT to Secondary
poles of next SmartSequencing device.
FO
+12V
P
FO
STAT
Secondary poles connect IN from Primary
P
COMM/
NO
poles of previous SmartSequencing device.
REM
POWER
S
NC
GND
S
NOTE: Chain units in series.
C
DELAY 3
DELAY 2
DELAY 2
OUTLET
BANK
IMPORTANT, PLEASE READ
DE-9 Communications port can also provide
power. Pin 2, Pin 3, and Pin 5 can be used for
non-Furman RS-232 devices and protocols.
Please verify pin assignment and protocol
of another manufacturer's device before
connecting to port.
• 877-486-4738
UNSWITCHED
UNSWITCHED
1
2
3
1
2
3
15 AMPS
15 AMPS
DELAY 1
N.O.
DELAY 1
1M
1M
2M
2M
4M
4M
START
START
N.C.
DLY
DLY
DELAY 2
DELAY 2
OFF
OFF
ADJ
ADJ
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
GND
GND
MOM
MOM
PRI
PRI
DELAY 3
SEQUENCE
SEQUENCE
DELAY 3
ON
ON
MNT
MNT
SEC
SEC
PUSH TO RESET
PUSH TO RESET
6
7
8
6
7
8
ETHERNET – Color indicates status of link communi-
cation with BlueBOLT cloud based platform.
LED OFF
Indicates no connection via BlueBOLT
adapter (e.g. BB-RS232)
GREEN
Indicates the unit has established active
communication through BlueBOLT adapter.
Please Note: The port is labeled COMM/POWER
and does provide 12VDC to suitable accessories.
Baud Rate 19200.
.
SMARTSEQUENCING
FORCE OFF
OUT
FO
P
FO
P
NO
S
NC
S
C
IN
DELAY 3
CLASS 2 WIRING
Delay 3 operates with Furman MP-20, ASD-120, etc.
DELAY 3
REMOTE PORT
+12V
STAT
REM
GND
DE-9 FEMALE CONNECTOR RS-232
DELAY 3
OUTLET
PIN NO.
PIN 1 - ACCESSORY POWER ONLY
ACCESSORY POWER ONLY
1
BANK
(NEGATIVE 12VDC RETURN)
(NEGATIVE 12VDC RETURN)
PIN 2 - TRANSMIT DATA
RECEIVE DATA
2
PIN 3 - RECEIVE DATA
TRANSMIT DATA
3
ACCESSORY POWER ONLY
4
PIN 4 - ACCESSORY POWER ONLY
SIGNAL GROUND
5
PIN 5 - SIGNAL GROUND
ACCESSORY POWER ONLY
6
PIN 6 - ACCESSORY POWER ONLY
REQUEST TO SEND
7
PIN 7 - REQUEST TO SEND
CLEAR TO SEND
8
PIN 8 - CLEAR TO SEND
ACCESSORY POWER ONLY
9
PIN 9 - ACCESSORY POWER ONLY
(POSITIVE 12V)
(POSITIVE 12V)
UNSWITCHED
UNSWITCHED
4
REMOTE
REMOTE
5
4
5
PRIMARY LINK
PRIMARY LINK
POWER
DELAY 1
12V ON
POWER
N.O.
12V ON
12V OFF
N.C.
12V OFF
SECONDARY LINK
SECONDARY LINK
PROTECTION OK
DELAY 2
PROTECTION OK
ON
ON
EVS AUTO
EVS AUTO
ETHERNET
ETHERNET
EXTREME VOLTAGE
DELAY 3
EXTREME VOLTAGE
MANUAL
MANUAL
9
9
Relay Barrier Strip (3)
FORCE OFF Provides immediate
shutdown by fire alarm
Delay 3 - Provides dry contact
COMM/
POWER
closures for relays
(max. 1A @ 24VDC)
SMARTSEQUENCING
FORCE OFF
OUT
FO
P
FO
P
COMM/
NO
POWER
S
NC
S
C
IN
DELAY 3
CLASS 2 WIRING
1
9
2
COMM/
8
3
POWER
7
4
6
5
4
DELAY 1
DELAY 2
DELAY 3