REAR LAMP
ON
OFF
Sequencing On/ Off Switch
This switch enables the power sequencing capabili-
ties of the PS-8RE III. This is NOT the power On/Off
switch.
Front Panel Covenience Outlet
Switched IEC C-13, 10A maximum.

Thermal Circuit Breaker

The overall current capacity of the PS-8RE III is 10 Amps.
This refers to the combined steady-state current drawn
by all devices plugged into all nine of its outlets. If the
combined steady-state current level exceeds 10 Amps,
the circuit breaker may trip, cutting off power to your con-

Rear Panel Features

AC ˜
220-240V
50/60Hz
10A MAX
AC Inlet IEC-C14, Male with Metal Retainer Clip
For connecting included 2.5 m AC Power Cord.
Switched Outlets Bank
With Swtched Outlets Bank LED indicator.
Delay 1, 2 and 3 Outlets Banks Sequenced:
Sequencing Enabling On/Off Switch on Front Panel
Delay Adjustment
The delay interval, which is the time between the
turn-on / turn-off of consecutive delay outlets 1 and 2,
or 2 and 3, is factory preset to approximately 5 sec-
onds. It is possible to lengthen or shorten the delay
interval by changing the position of the DLY-ADJ trim
pot located on the right side of rear panel.
.
DELAY 1
DELAY 2
DELAY 3
PS-8RE III
SWITCHED
POWER
DELAY 1
SEQUENCE
EXTREME
PROTECTION
POWER
VOLTAGE
OK
nected equipment. If this occurs, you must reduce the
load by unplugging one or more devices from the PS-
8RE III. Then push the button on the front panecircuit
breaker to reset it. Although 10 Amps is an absolute limit,
the PS-8RE III's power sequencing capability will allow
you to come as close as possible to using the full 10
Amps, because the risk of tripping the breaker is greatly
reduced by sequencing on loads, thus allowing each
stage to settle to its steady-state current draw before the
next stage is powered.
Main Power On/Off Switch:
PS-8RE III main power On/Off swith with LED indicator
on front panel. Rear panel indicator for the Switched Out-
lets bank.
AC ˜
220-240V
50/60Hz
10A MAX
DELAY 2
DELAY 3
The delay adjustment procedure is simple and re-
quires a small standard screwdriver. The DLY ADJ
(delay adjustment) is a trim pot that is located on the
rear of the PS-8RE III above the legacy interface and
to the left of the DIP Switches. Locate the rectangu-
lar slot in the center of the trim pot and use a screw-
driver the rotate the trim pot to set your desired delay
The minimum delay (1/2 Second) is achieved when
the trim pot is adjusted fully counter-clockwise. The
maximum delay (~10 Seconds) is achieved when the
pot is rotated fully clockwise.
DLY-ADJ
Position Stage
Delay
Full CCW
12 o'clock
Full CW
4
SWITCHED
MAIN POWER
10 AMPS
ON
OFF
PUSH TO RESET
AC ˜ 220-240V 50/60Hz 10A MAX
12V ON
1
1 2 3
12V OFF
MOM
3
MNT
DLY
ADJ
12V STAT REM GND
REMOTE PORT
12V ON
1
1 2 3
12V OFF
12V STAT REM GND
REMOTE PORT
½ Second
5 Seconds
10 Seconds
ON
OFF
GND
2
ON
12V 0.5A
GND
2
ON
MOM
3
MNT
12V 0.5A