SPECIFICATIONS
Maximum AC Current Rating:
• CN-1800S: 15 Amps, 120 VAC (Thermal breaker)
• CN-2400S: 20 Amps, 120 VAC (Thermal breaker)
AC Cord:
• CN-1800S: 3/14 AWG, 10 feet, black, fixed, NEMA 5-15P plug
• CN-2400S: 3/12 AWG, 10 feet, black, fixed, NEMA 5-20P plug
AC Receptacles:
• Convenience Outlet (Front Panel) 1 Unswitched NEMA 5-15R
• CN-1800S Rear Panel Outlets: 2 Unswitched NEMA 5-15R (1 duplex),
• 6 Sequenced NEMA 5-15R (3 duplexes each controlled by separate relay)
• CN-2400S Rear Panel Outlets: 2 Unswitched NEMA 5-20R (1 duplex),
• 6 Sequenced NEMA 5-20R (3 duplexes each controlled by separate relay)
Surge/Under-Overvoltage Protection:
• AC Surge Protection: SMP
• Spike Protection Mode: Line to neutral, zero ground leakage
• Spike Clamping Voltage: 188VAC peak @ 6,000 Volts/3,000 Amps
• Response Time: 1 nanosecond
• Maximum Surge Current: 6,500 Amps
• AC Undervoltage Protection: EVS, 77VAC+/-3VAC
• AC Overvoltage Protection: EVS, 145VAC+/-5VAC
• AC Overvoltage Reset Modes: Manual and Auto-reset (configurable)
AC Filtering:
• LiFT
• Noise Attenuation: Linear, 10dB @10KHz, 40dB@100KHz, 50dB@500KHz
Operating Temperature Range: • 5C (40F) to 40C (105F) degrees
Humidity Range: • <90% rH (Relative Humidity)
Specifications subject to change due to product upgrades and improvements.
WARRANTY INFORMATION
15 YEAR LIMITED PRODUCT WARRANTY*
Furman warrants to the original purchaser of this product for a
period of fifteen (15) years from the date of purchase, that the
unit shall be free of defects in design, material or workman-
ship, and Furman will repair or replace any defective unit.
Full Warranty and Policy information available at
www.furmancontractor.com
7
User Interface:
• Keyswitch: Front panel, 3-position keyswitch (On, Off, Remote)
• Keys: Included, 1 pair
• Pushbutton Switch: Front panel, hidden by security cover
• Thermal Circuit Breaker: Front panel, pushbutton
• Front panel diagnostic indicators: Primary link, Secondary link, Ethernet,
Delay 1, Delay 2, Delay 3, Power, Protection OK, Extreme Voltage
• Front Panel DIP Switches: Front panel. hidden by security cover, 1 Minute Delay,
2 Minute Delay, 4 Minute Delay, Force Off NO/NC, 12V Mode On/Off, GND Mode On,
Momentary/Maintained, Primary/Secondary, EVS Reset Auto/Manual
• Potentiometer: Front panel, time calibration hidden by security cover,
fine tune delay adjust
Control/Status/Triggering (Rear Panel):
• Remote Terminal: +5-30VDC In, 12VDC (12mA) Out
• SmartSequencing: Phoenix type 4-Pin Connector, with Screw Terminals, Primary &
Secondary Links (Current Loop - 1000' nominal)
• Remote Terminal: Phoenix type 4-Pin Connector with Screw Terminals; +12V, STAT,
REM, GND (Class 2 Wiring)
• Force Off/Delay 3 Terminal: Phoenix type 5-Pin Connector with Screw Terminals,
FORCE OFF, DELAY 3 (Class 2 Wiring)
• RS-232 Compatible: DE-9 Connector
• IP Addressability: Optional, via BB-RS232 Ethernet/RS-232 Adaptor (sold separately)
for IP control via BlueBOLT®
• Voltmeter: Available with RS-232 and other options, +/- 1VAC accuracy
• Ammeter: Available with RS-232 and other options, +/-0.3 A accuracy
Power Consumption (No Load): • 10 Watts
Safety Agency: • NRTL-C
CSA/NRTL Compliant:
CAUTION! WARRANTY LIMITATION FOR INTERNET PURCHASERS
Furman products purchased through the Internet do not carry a valid
Product Warranty unless purchased from an Authorized Furman
Internet Dealer and the original factory serial numbers are intact
(they must not have been removed, defaced or replaced in any way).
Purchasing from an Authorized Furman Internet Dealer insures that
the product was intended for consumer use, has passed all quality
inspections and is safe. Buying through auction sites or unauthorized
dealers may result in the purchase of salvaged, failed and/or products
not intended for use in the US. In addition, Authorized Furman Internet
dealers have demonstrated sufficient expertise to insure warranty
compliant installations.
For a list of Authorized Furman Internet Dealers
go to www.furmansound.com
DQS-00006-C