Installation
Installation procedures and specifications are presented in detail in the In-Sight
Micro Series Vision System Installation Manual, which is installed with In-Sight
Explorer software. From the Windows Start menu, select the following to access the
manual: All Programs > Cognex > In-Sight > In-Sight Explorer x.x.x >
Documentation.
Note:
Cables are sold separately.
l
If any of the standard components appear to be missing or damaged,
l
immediately contact your Cognex Authorized Service Provider (ASP)
or Cognex Technical Support.
Install the Mounting Block (Optional)
Use the mounting block to secure the vision system to a mounting surface.
1. Align the mounting block with the mounting holes on the vision system.
2. Insert the M3x6 (quantity 4) screws into the mounting holes and tighten the
screws using a 2.5mm hex wrench; the maximum torque is 0.9039 Nm (8
in-lb).
Install the Lens
1. Remove the protective lens cap and the protective film covering the image
sensor, if present.
2. Attach a CS-Mount or C-Mount (with 5mm extension ring) lens to the vision
system. The exact lens focal length needed depends on the working
distance and the field of view required for your machine vision application.