3
Transport and storage
3.1
Inspection of condition on delivery
Inspect the ov erflow valve for damage upon receipt.
In case of transport damage, determine and document the precise extent of the damage, and
report it immediately to the supplying dealer/carrier and the insurer.
3.2
Transportation
Transport the ov erf low v alve in the supplied packaging.
The ov erf low v alve is delivered in a ready -to-operate state with the connections protected by
caps.
Protect the ov erflow v alve against shocks, impacts, vibration and dirt.
Adhere to a transport temperature range of -20 °C to +65 °C.
3.3
Storage
Store the ov erf low v alve in a clean and dry place.
Make use of a desiccant or heating in damp storerooms to prevent the formation of
condensation.
Adhere to a storage temperature range of -20 °C to +65 °C.
4
Description of the overflow valve
Ref er to the respective catalogue page f or further and detailed inf ormation.
4.1
Structure
Design
Directly acting angle overflow valve, spring-loaded.
4.2
Marking
The ov erf low v alves are provided with an indiv idual marking for identification.
Symbol
e.g. G1/2
PN.....
e.g. CC491K
0045
e.g. 06195
01.18
N
P
F
-.....°C - +.....°C
Axx.x
x.xx bar
16
Operating instructions
Explanation
Connection size
Nominal pressure (max. permissible operating pressure)
Manuf acturer's mark "HEROSE"
Material
CE mark, ID of notified body only from size 1-1/4"
Ty pe
Date of manuf acture MM/Y Y
NBR
PTFE
FPM
min / max. temperature
Narrowest f low cross-section A in mm²
Setting pressure
Phone +49 4531 509-0