30
Product No. 085-1577-0 • Model No. FHTS80021D
Burner will not
light using
igniter
Burner will not
light with match
LP gas tank valve is closed
LP gas tank is low or empty
LP gas leak
Battery needs to be changed
Electrode and burners are wet
Electrode cracked or
broken — sparks at crack
Wire loose or disconnected
Wire is shorting (sparking)
between igniter and electrode
Bad igniter
No gas flow
LP gas tank is low or empty
LP gas leak
Coupling nut and regulator
not fully connected
Obstruction of gas flow
Disengagement of
burner to valve
Spider webs or insect nest
in burner/venturi tube
Burner ports clogged
or blocked
Make sure regulator is securely attached to
the LP gas tank per "Installing LP Gas Tank,"
then turn LP gas tank valve to "OPEN"
Exchange, refill or replace LP gas tank
1. Turn LP gas tank valve to "CLOSED"
2. Wait 5 minutes for gas to clear
3. Follow "Checking for Leaks" section
Replace the "AA" battery (follow assembly
step for inserting battery)
Wipe dry with cloth
Replacement part(s) may be needed —
contact Customer Care at 1-877-483-6759
Replacement part(s) may be needed —
contact Customer Care at 1-877-483-6759
Replacement part(s) may be needed —
contact Customer Care at 1-877-483-6759
Replacement part(s) may be needed —
contact Customer Care at 1-877-483-6759
Check if LP gas tank is empty
a. If empty, exchange, refill or replace LP gas tank
b. If LP gas tank is not empty, refer to "Sudden drop
in gas flow or reduced flame height" (see below)
Exchange, refill or replace LP gas tank
1. Turn LP gas tank valve to "CLOSED"
2. Wait 5 minutes for gas to clear
3. Follow "Checking for Leaks" section
Turn the coupling nut about one-half to
three-quarters additional turn until solid stop.
Tighten by hand only — do NOT use tools
1. Clear burner/venturi tube
2. Check for bent or kinked hose
Re-engage burner and valve
Clean burner/venturi tube
Clean burner ports