Connect the Input and Output Wires
(Optional)
1. Determine how I/O devices will be connected to the I/O module's input and
output terminals.
2. Use a screwdriver to loosen the appropriate screw terminals.
3. Insert the input and output wires (16 - 22 AWG, solid or stranded wire) to
the input and output terminals. Connect the other end of the input and
output wires to the applicable I/O device.
4. Tighten the screw terminals with the screwdriver to secure the wire leads in
the terminal block; the maximum torque is 0.1921 Nm (1.7 in-lb).
Connect CC-Link Wires (Optional)
Note: The CC-Link terminals are only available on the CIO-MICRO-CC I/O
module.
1. Determine how CC-Link devices will be connected to the I/O module's CC-
Link terminals.
2. Use a screwdriver to loosen the appropriate screw terminals.
3. Insert the CC-Link wires (using a CC-Link specified cable) to the CC-Link
terminals and the other end of the cables to the applicable CC-Link devices.
4. To reduce emissions, attach a Steward 28A0640-0A2 ferrite around the
CC-Link wire bundle, as close to the connector as possible.
9