Mode Management Sub-Menu; General Sub-Menu - Tractel dynafor HHD Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 21
A
"Mode management" sub-menu (see section5.5.8.1)
B
"General" sub-menu (see section 5.5.8.2)
GB
To return to the main menu, hold down (for one second)
the left button.

5.5.8.1. Mode management sub-menu

The "Mode management" sub-menu is entered by
pressing the "OK" button briefly (item E, fig. 1) when the
.5.8.1
"Mode management" icon is highlighted.
A
Reading frequency, adjustable from 1 to 4 Hz
B
Automatic sleep mode setting
C
Automatic power-saving mode setting
D
Remote sensor sleep
E
Remote sensor shutdown
The navigation in the sub-menu is done by using the up
and down buttons. The round, blue indicator updates
according to the position.
The fields are set by pressing the "OK" button then
the up and down buttons. The values are validated by
pressing the "OK" button briefly.
The modes are activated/deactivated by pressing the
"OK" button briefly.
NB: The factory default for automatic sleep and
power-saving modes are active (20 min and 5 min/10%
respectively).
NB: The power-saving mode is activated
after no load change for a period of time, in order to
preserve the sensor batteries. The reading frequency
of the sensor switches to 1 Hz. A change in load causes
the sensor to switch back on as normal (measuring
frequency 4 Hz).
NB: The automatic sleep mode is activated
after no load change (10% of the SWL of the sensor).
It causes the measurements to stop and preserves the
12
batteries. The sensor returns to normal operation after
switching the dynafor™ HHD back on.
To return to the "Parameters" menu, hold down (for one
second) the left button. The changes are taken into
account when you return to the "Parameters" menu.

5.5.8.2. General sub-menu

§5.5.8.2
The "General" sub-menu is entered by pressing the
"OK" button briefly (item E, fig. 1) when the "General"
icon is highlighted.
A
B
C
D
E
A
Measurement unit setting
B
Backlighting setting
C
Configuration of the master or slave mode (see
5.5.8.2)
D
Measurement filter setting. This filtering enables
sliding averaging of the measurements over a fixed
period.
The factory default setting is 0.5 seconds.
E
Thresholds trip filter setting. This limits the dynamic
effects on a threshold trip. The factory default setting
is 0 second. This filtering is not used in connection
with the use of this product.
F
Radio communication channel configuration.
G
Date and time setting
The navigation in the sub-menu is done by using the up
and down buttons. The round, blue indicator updates
according to the position.
The units and configuration mode are set by pressing
the left and right buttons.
The other fields are set by pressing the "OK" button
then the up and down buttons. The values are validated
by pressing the "OK" button briefly.
NB: Changing the channel causes the loss
of the paired sensors. Ten channels are available,
allowing several configurations.
NB: Before changing from master to slave
mode, see chapter 5.5.18.
A
B
C
D
E
F
G

Publicité

Table des Matières
loading

Table des Matières