Bosch 1500 Mode D'emploi page 11

Masquer les pouces Voir aussi pour 1500:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

The bathroom extractor fan is designed for permanent indoor connection, for
xed electrical installation, which must be equipped with means/devices for total
contact breakage in order to ensure complete separation under overvoltage
conditions of category III according to the regulations for such installation.
The bathroom extractor fan is designed for installation at a substantial height, i.e.
2 m above the oor. Installation - only in accordance with the descriptions and
guidelines in this manual, in particular with regard to the required installation
position, by inserting the power cord into the housing.
• Measures shall be taken to prevent gases from escaping from open smoke duct or other open ame
equipment into the room.
• Unauthorised changes or modi cations to the equipment are not permitted.
• Before installing the equipment, check the load-bearing capacity of the structure to which it is to be
mounted, as improper mounting can lead to damage or destruction of the equipment and can pose
a risk to persons in the vicinity of the equipment in the following situations.
The appliance may become dangerous if used improperly or if installed by unqualified
personnel.
3 APPLICATION AND OPERATING CONDITIONS
• Bathroom extractor fans are designed to transport normal or slightly dusty air (particle size <10 m)
of low aggressiveness and humidity in temperate climates according to and within their limits of
performance.
• The appliance is designed only for continuous operation in a building if there is no access to the
power supply line.
• The maximum temperature of the medium handled by the bathroom extractor fan and the
maximum ambient temperature are +40°C.
• The exhaust fan is an IPX4 and protection class II device. The exhaust fan can be installed in indoor
moisture Zone 2, ref. IEC 60364-7-701, provided that the following requirements from the exhaust
fan manufacturer are complied with:
1 - the correct wall-mounting position is maintained with a proper seal of the power cord in the
grommet (see Installation section).
2 - the exhaust duct is secured by a cover from direct exposure to water per IP24 and direct access to
live and/or rotating parts, including the fan rotor in motion; or the exhaust duct is at least 800 mm
long and installed with special tools which will be required to access the exhaust fan.
• The bathroom extractor fan must be operated according to its intended use and in accordance with
the data provided on the rating plate.
• The bathroom extractor fan must be connected to the building mains (electrical system) with the
following power cable: NYM-O 2x1.5 mm² (H07V-K 2x1.5 mm²) or NYM-O 3x1.5 mm² (H07V-K 3x1.5
mm²), maximum outer diameter 7.5 mm, depending on the optional accessories provided (does not
apply to the models with the power cord attached).
Fan 1500, Fan 1500 DH
11

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

1500 dh

Table des Matières