The bathroom extractor fan is designed for permanent indoor connection, for
xed electrical installation, which must be equipped with means/devices for total
contact breakage in order to ensure complete separation under overvoltage
conditions of category III according to the regulations for such installation.
•
The bathroom extractor fan is designed for installation at a substantial height, i.e.
2 m above the oor. Installation - only in accordance with the descriptions and
guidelines in this manual, in particular with regard to the required installation
position, by inserting the power cord into the housing.
• Measures shall be taken to prevent gases from escaping from open smoke duct or other open ame
equipment into the room.
• Unauthorised changes or modi cations to the equipment are not permitted.
• Before installing the equipment, check the load-bearing capacity of the structure to which it is to be
mounted, as improper mounting can lead to damage or destruction of the equipment and can pose
a risk to persons in the vicinity of the equipment in the following situations.
The appliance may become dangerous if used improperly or if installed by unqualified
personnel.
3 APPLICATION AND OPERATING CONDITIONS
• Bathroom extractor fans are designed to transport normal or slightly dusty air (particle size <10 m)
of low aggressiveness and humidity in temperate climates according to and within their limits of
performance.
• The appliance is designed only for continuous operation in a building if there is no access to the
power supply line.
• The maximum temperature of the medium handled by the bathroom extractor fan and the
maximum ambient temperature are +40°C.
• The exhaust fan is an IPX4 and protection class II device. The exhaust fan can be installed in indoor
moisture Zone 2, ref. IEC 60364-7-701, provided that the following requirements from the exhaust
fan manufacturer are complied with:
1 - the correct wall-mounting position is maintained with a proper seal of the power cord in the
grommet (see Installation section).
2 - the exhaust duct is secured by a cover from direct exposure to water per IP24 and direct access to
live and/or rotating parts, including the fan rotor in motion; or the exhaust duct is at least 800 mm
long and installed with special tools which will be required to access the exhaust fan.
• The bathroom extractor fan must be operated according to its intended use and in accordance with
the data provided on the rating plate.
• The bathroom extractor fan must be connected to the building mains (electrical system) with the
following power cable: NYM-O 2x1.5 mm² (H07V-K 2x1.5 mm²) or NYM-O 3x1.5 mm² (H07V-K 3x1.5
mm²), maximum outer diameter 7.5 mm, depending on the optional accessories provided (does not
apply to the models with the power cord attached).
Fan 1500, Fan 1500 DH