Step 4. Installing the power cord
For power cord installations, hook the strain relief over the power cord hole (1
below the rear of the drawer body. Insert the power cord through the strain relief and
tighten the device.
Power cord
• You must install the power cord with a strain relief.
• Attach the strain relief to the 1
Installing a 3-wire power cord
WARNING
The neutral or ground wire of the power cord must be connected to the neutral terminal
located in the center of the terminal block. The power leads must be connected to the lower
left and the lower right terminals of the terminal block.
Neutral
terminal
White
Black
White
Black
Conduit connection plate
Strain relief
/
" opening in conduit connection plate.
3
8
Ground strap
Red
Red
1. Remove the 3 lower terminal screws from
the terminal block.
2. Insert the 3 terminal screws through each
power cord terminal ring and into the
lower terminals of the terminal block.
Be certain that the center wire (white/
neutral) is connected to the center lower
position of the terminal block.
3. Tighten screws securely into the terminal
block. DO NOT remove the ground strap
connection.
4. Go to step 6 on page 34 and proceed with
the installation.
/
") located
3
8