Rear Panel Connectors
1
2
Figure 3
#
Item
Kensington
This is used to attach a physical Kensington
1
Lock Input
security lock.
2
Switch GND
This is used to connect the switch to ground.
Power Cord
This is used for securing the power cord
3
Retainer Slot
retainer to the switch.
Power Adapter
This is used to connect the power cable to the
4
Input
switch.
Table 3
Hardware Installation
Before You Begin
Observe the following precautions to help prevent
shutdowns, equipment failures, and personal injury:
•
Install the DGS-1026MP in a cool and dry
place. Refer to the technical specifications in
the user manual for the acceptable operating
temperature and humidity ranges.
•
Install the switch in a site free from strong
electromagnetic sources, vibration, dust, and
direct sunlight.
•
Leave at least 10 cm of space at the left and right-
hand side of the switch for ventilation.
•
Visually inspect the power connector and make
sure that it is fully secured to the power cord.
•
Do not stack any devices on top of the switch.
Using the Switch on a Flat Surface
The DGS-1026MP comes with a set of adhesive
rubber feet which allow the switch to be placed on
a flat surface such as a desk or table, without risk of
damaging it. To attach the rubber feet, simply place
one in each corner of the bottom panel of the switch.
Figure 4
3
4
Description
Mounting the Switch in a Rack
The DGS-1026MP can be mounted into a standard
19" server rack. The following instructions will explain
how to install the switch into a rack:
1. Attach the included mounting brackets to each
side of the switch's chassis and secure them to
the device using the provided screws.
Figure 5
2. Use the screws that were provided with the rack
to install the switch in the rack.
Figure 6
Grounding the Switch
This section will provide step-by-step instructions
on how to connect the switch to ground. This step
must be completed before powering on the switch.
Required tools and equipment for grounding
•
Grounding screw (included) and one M4x6
(metric) pan-head screw (not included).
•
Grounding cable (not included). The grounding
cable should be sized according to local and
national installation requirements. Depending
on the power supply and system, a 12 to 6 AWG
copper conductor is required for installation.
Commercially available 6 AWG wire is
recommended. The length of the cable depends
on the proximity of the switch to proper
grounding facilities.
•
A screwdriver (not included).
3