ELITE EXECUTIVE OWNER'S MANUAL
Turn the synchronous detector off while tuning stations or
when it's not needed. Using the Wide/Narrow button may also
help. Using the synchronous detector does not always minimize
interference or improve the signal.
Turn the synchronous detector off while tuning stations or
when it's not needed. Using the Wide/Narrow button may also
help. Using the synchronous detector does not always minimize
interference or improve the signal.
USING DX/LOCAL SWITCH
The DX/local switch (left side panel) adjusts sensitivity. Use DX (down) as
the default setting for maximum sensitivity to signals. If strong stations
or SSB signals seem distorted, then use Local (up). If tune in the weak
signal station,use DX.
DC IN JACK
Plug the input jack into DC in jack to connect external AC adapter
to power supply the ELITE EXECUTIVE according to polarity on
labeling, "
" icon appears in the display.
Note: AC power may have interference with the reception for AM(MW),so it may be
better to listen to the ELITE EXECUTIVE using batteries and disconnect to external AC
adapter to get the best reception.
CHARGING NI-MH BATTERY IN THE ELITE EXECUTIVE
With its included AC adapter/charger connected, the ELITE
EXECUTIVE internally recharges 4 Ni-MH rechargeable
batteries(not included).
To Charge batteries:
1.) Connect the AC adapter/charger,
icon appears in the LCD;
2.) With the ELITE EXECUTIVE turned off, install 4 Ni-MH batteries
and connect the AC adapter;
3.) Press and hold the F7 button until CHARGE XX appears in the
display;
4.)Use the tuning knob to select the charging time in hours (1~36)
based on the mAh rating of your batteries, CHARGE 00 indicates
not charging. Normally 11 hours for 1100mAh rating; 23 hours for
2300mAh rating etc.
5.)Quick press PAGE/TIME button when finished, the charging
begins, the charging icon
is rolling, which means on-charging.
If the battery is fully charged or the charging time set is over, the
charging is completed.