The meter can be configured to use litres [L],
gallons [G
], pints [p
al
When making a change from one unit to
another the conversion of the quantity stored
is made both in the partial meter and in the
total meter.
Combination no.
1
2
3
4
To choose between the 4 available combinations:
1
Wait for the meter to go to Standby
2
Then press the CAL and RESET keys together. Keep these pressed until the
word "UNIT" appears on the screen together with the unit of measure-
+
ment set at that time (in this example Litres / Litres).
Every short press of the RESET key, the various combinations of the units
of measurements are scrolled as shown below:
3
4
By pressing the CAL key at length, the new settings will be stored, the
meter will pass through the start cycle and will then be ready to dispense
in the set units.
ATTENTION
The Reset Total and Total registers will be automatically chan-
ged to the new unit of measurement.
NO new calibration is required after changing the Unit of Mea-
surement.
Samoa Industrial, S.A. · Box 103 Alto Pumarín · 33211 Gijón - Asturias Spain · Tel.: +34 985 381 488 · Fax.: + 34 985 384 163
Change in measuring units
] or quarters [Q
ts
ts
Unit of Measurement
Partial Register
Litres
(L)
Gallons (G
)
al
Quarts (Q
)
ts
Pints (p
)
ts
The combination of the unit of measurement
].
of the Partial register and that of the Totals is
predefined according to the following table:
Unit of Measurement
Totals Register
Litres (L)
Gallons
Gallons (G
Gallons (G
G
al
Q
ts
(G
)
al
)
al
)
al
P
ts
G
al
R. 10/12 836 828