SETTING
Scroll until
"menu Settings"
then press "P3"
m e n u
S e t t i n g s
26
A6U48 - A10U48
Mid & Long Range UHF Reader
Scroll to desire
selection then
press "P3"
The interval is the time between each reading of the same
S e t t i n g s
serial number which remains in the range of the reader .
I n t e r v a l
Set to: 0, 5, 10, 20 or 30 sec. (default: 10 sec.)
The deadtime is the time that a tag must stay out of the
S e t t i n g s
detection zone before time to be re-detected at-once.
D e a d T i m e
Set to: 0, 1, 2, 3, 4, 5, 6, 7, 8 or 9 sec. (defaut 5 sec.)
S e t t i n g s
A n t e n n a 1
A n t e n n a
A d d r e s s
A n t e n n a 1
A n t e n n a 2
A d d r e s s
A n t e n n a 2
IMPORTANT NOTE:
(1) At the first power up, the antenna address is populated automatically with its
serial number when the first UHF credential will be read by the antenna.
Read a UHF credential to know the address position (1 or 2) of an antenna. The
RF module will display "A1" for address 1 and "A2" for address 2 of an antenna.
To replace a defective antenna you must manually reset its address to "00000",
connect the new antenna and then pass a UHF badge to automatically populate
the new address.
(2) See section 14 for Wiegand format details.
D e l e t e
Sets the receiver to the factory default settings.
S e t t i n g s
See note (1)
A d d r e s s 1
0 0 0 0 1
Set the Wiegand code of the antenna:
1 to 9 (default: 1). See note (2)
W i e g a n d 1
C o d e
See note (1)
A d d r e s s 2
0 0 0 0 2
Set the Wiegand code of the antenna:
1 to 9 (default: 2). See note (2)
W i e g a n d 2
C o d e
EN
1
2

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

U4go a6u48U4go a10u48F0103000125F0103000127