OPERATING THE UNIT

Removing the collected water

There are three ways to remove collected water.
1. Use the bucket
When the unit is off, if the bucket is full, the Full indicator
light will illuminate.
When the unit is on, if the bucket is full, the compressor
and the fan turn off, and the Full indicator light will light,
the digital display shows P2.
Slowly pull out the bucket. Grip the left and right
handles securely, and carefully pull out straight so
the water does not spill. Do not put the bucket on the floor
because the bottom of the bucket is uneven. Doing so will
cause the bucket to fall and the water to spill.
Throw away the water and replace the bucket. The
bucket must be in right place and securely seated for the
dehumidifier to operate.
The machine will re-start when the bucket is restored
in its correct position.
NOTES:
When you remove the bucket, do not touch any parts
inside of the unit. Doing so may damage the product.
Be sure to push the bucket gently all the way into the
unit. Banging the bucket against anything or failing to
push it in securely may cause the unit not to operate.
If the pump hose drops when you remove the bucket
(see Fig.7),you must reinstall the pump hose properly
to the unit before replace the bucket into the unit
(see Fig.8).
When you remove the bucket, if there is some water in
the unit you must dry it.
When the unit is on, if the bucket is removed, the
compressor and the fan turn off, then the unit will beep
8 times and the digital display shows Eb.
When the unit is off, if the bucket is removed, the unit
will beep 8 times and the digital display shows Eb.
2. Continuous draining
Water can be automatically emptied into a
drain by attaching the unit with a water hose
(Id
5/16 , not included) with a female threaded
end (ID:M=1 , not included)
Remove the plastic cover from the back drain outlet of
the unit and set aside, then insert the drain hose through
the drain outlet of the unit and lead the drain hose to
and Fig.10)
When you remove the plastic cover, if there is some
water in the back drain outlet of the unit you must dry it.
Make sure the hose is secure so there are no leaks and
the end of the hose is level or sloping downward allowing
the water to ow smoothly.
Direct the hose toward the drain, making sure that
there are no kinks that will stop the warter ow.
Select the desired humidity setting and fan speed on the
unit for continuous draining to start.
NOTE: When the continuous draining feature is not being used,remove the drain hose from the outlet,
and dry the water in the continuous drain hose outlet.
r
8
NOTE: When the continuous draining feature is not being used, remove the drain hose from
the outlet, and dry the water in the continuous drain hose outlet.
Removing the collected water
3. Pump draining (on some models)
Water can be automatically emptied into a floor
drain by attaching
the pump drain out with a pump drain hose
( od=1/4 , supplied).
Remove the continuous drain hose fromthe unit and install
the plastic cover to the continuous drain hose outlet of the
unit by clockwise rotation.(See Fig.11).
Resert the pump drain hose into the pump drain hose
outlet for depth of 15mm at least (See Fig.11), then lead
the water hose to the floor drain or a suitable drainage facility.
Press the pump pad of the unit to activated the pump
operation. When the bucket is full the pump starts to work.
NOTE: The pump may cause a loud noise when it starts to
work for 3~5 minutes, this is normal.
Make sure the hose is secure so there are no leaks.
Direct the hose toward the drain, making sure that there
are no kinks that will stop the warter flow.
Place the end of the hose into the drain and make sure
the end of the hose is level or sloping downward allowing
the water to flow smoothly.Never have the water flow upwards.
Select the desired humidity setting and fan speed on the
unit for pump draining to start.
NOTE: The pump operation on light blinks at 1Hz when the
pump is in operational failure. Please turn off the unit and unplug
the power cord. Check the following things:
Cleaning the filter of the pump.
Remove the bucket from the unit, take down the pump
and clean the filter of the pump (See Fig.12).
Check that the pump drain hose is not kinked or blocked.
Empty the water of the bucket.
Reinstall the pump hose if it drops and reinstall the bucket
properly. Turn on the unit. If the error repeats, call for service.
OPERATING THE UNIT
NOTE: Do not use this operation when the outdoor temperature
is equal to or less than 0 C (32 F),otherwise the water becomes ice
and this may cause the water hose to get blocked up which may
cause the unit to fail.
Make sure to empty the bucket once a week when using
the pump draining feature. When the pump draining feature is
not being used, remove the pump drain hose from the outlet.
Press the pump drain hose outlet in and take the pump drain hose
out from it (See Fig.13). Make sure to not let the water in the pump
hose drip onto the floor.
OPERATING THE UNIT
Reinstall the
plastic cover
Pump drain
hose outlet
Pump drain
hose
Fig.11
Filter of the pump
2,Take the pump
drain hose out
1,Press the pump drain
hose outlet in
Fig.13