9) Remove the leveling leg in the back left corner. See Fig-
ure 7. Insert the drain pump into the rear of the cabinet so
the tubing connections are positioned as shown.
10) Insert and position the foam shipping block above
the drain pump behind the tubing connections so it rests
between the top of the drain pump and the bottom of the
cabinet.
11) Connect power cord wire connector to the drain pump
wire connector (see Figure 7a), and attach the drain pump
ground wire to the back flange of the cabinet base where
shown in Figure 7. Plug the male plug from the 18" wire
harness into the outlet on the side of the drain pump.
Drain pump ground wire, fasten to
cabinet back flange, see Figure 7.
Shipping
block
Leveling leg
Attach drain pump
ground wire here
(step 9)
DRAIN PUMP INSTALLATION
12) With the hose clamps from the drain pump kit connect
the 18" vent tube, the 20' discharge tubing, and the drain
tee to the drain pump as shown in Figures 7 and 7a.
When replacing tube clamps, do not overtighten which
could damage the tubing. Tighten screws until "snug", then
retighten several minutes later after the material relaxes, to
assure a water tight connection.
13) Re-install the leveling leg to its original position.
Figure 7a
18" (45.7 cm)
vent tube
20' (6.1 meters)
discharge tubing
Drain tee
Figure 7
6
CAUTION
!
Service cord and drain
pump wire connectors
(step 9)
Male plug from 18"
(45.7 cm) wire harness.