The following items require review on a regular basis.
Check that the ice bin drain inside the cabinet is open
and free of foreign material which would block water
flow to the drain pump, see Figure 12.
Check that the inlet tubing from the ice machine drain
valve to the drain pump is open and free of foreign
material. Inspect the screen at the top of the inlet tube
to ensure there is nothing blocking the water flow to the
pump, see Figure 13.
Check that the vent line is open, free of kinks and sharp
bends so that the air can flow freely from the pump
reservoir. See Figure 9 on page 8.
Check that the discharge tubing is free from foreign
material (algae, etc.) and kinks and bends. Pour water
in the ice bin to confirm that the check valve is opera-
tional by observing that the water flow is evident in one
direction only, out of the pump. Remove and clean as
required.
NOTE
If the drain line is restricted, or the drain pump malfunc-
tions, and the drain pump reservoir (not the ice machine
ice storage bin) reaches overfill condition, the power to the
ice machine will be shut off.
MAINTENANCE
Drain pump
inlet screen
10
Ice bin
drain
Figure 12
Figure 13