4.0
INSTALLATION
4.1 Positioning
– If positioned near a wall, the back must be at a minimum distance of 8
cm from this wall (Fig.4.1), so as to allow normal ventilation of the cooling
unit. Never cover the distributor with cloths or similar objects.
– Position the distributor and level it using the pre-mounted adjustable feet
(Fig.4.2). Make sure that the distributor does not have an inclination of
more than 2°.
– Make sure that the grates behind and under the radiator are always free
and not obstructed by dust or similar objects in order to guarantee perfect
ventilation of the cooling unit.
– It is recommended that the distributor be fixed to the wall using
the two brackets provided. Fix them first to the distributor (fig.4.3)
and then to the wall.
WARNING! Do not position the device near inflammable objects, keep a
minimum safety distance of 30 cm.
Bianchi Industry declines every responsibilty for any damage due to
the non-observance of the rules about machine positioning.
If the machine is installed in an emergency exit corridor, ensure that when
the distributor door is open there is still enough space to pass. (Fig.4.1).
4.2 Main Power supply connection
The distributor is predisposed to function with mono-phase 220-230V, 50Hz
tension of net and is protected with 10A fuse.
We suggest to check that:
– the tension of net doesn't have a difference of more than ± 6%
– The power supply output is able to bear the power load of the machine.
– use a system of diversified protection
– position the machine in such a way as to ensure that the plug remains
accessible
The machine must be connected to earth in observance with the current
safety norms.
For this reason, verify the plant's earth wire connection to ascertain that it
is efficient and it answers national and European safety electric standards.
If necessary require the intervention qualified personnel for the verification
of the plant.
– The distributor is equipped with a power supply cable of H05VV-F 3x1
mm², with CEE 7/7 plug (NBR 14136:2001 plug - IRAM 2073 10A plug)*
(Fig.4.4).
– The sockets that are not compatible with that of the machine must be
replaced. (Fig.4.5).
– The use of extension, adapters and/ or multiple plugs is forbidden.
– In some models, specific plugs are assembled for the destination place.
Bianchi Industry declines all responsibility for damages deriving for the
complete or partial failure to observe these warnings.
Should the power cable be found to be damaged, immediately disconnect
from the power socket.
The power supply cables are to be replaced by skilled personnel.
* Special versions for the domestic market
4.3 Starting up of the unit
The distributor is equipped with safety switch (Fig.4.6) that disconnects the
machine whenever the door is opened (see electric schema).
In case of necessity, therefore, open the door or disconnect taking of the
machine from the power supply.
– For some operations is however necessary operate with the door open
but with the distributor connected.
It is possible for qualified technical personnel, to operate in this way, by
inserting the special plastic key , supplied with the distributor, into the
door switch and rotating it 90° (Fig.4.7).
The clamp of the power cable junction box under tension
(Fig.4.8)
The opening and the possible connection with the distributor's door
open must be performed only by authorized and technically qualified
personnel. Don't leave the distributor open and unguarded.
Give the key only to qualified personnel.
Every time the distributor is switched on, a diagnosis cycle begins to check the
position of the parts in motion and the number of motors there are per drawer.
4.4
Refrigerator unit
The dispenser is equipped with a refrigerating unit to ensures a cooling tem-
perature range of 2°C to 15°C, depending on the machine settings (drawers
and configuration).
-
The internal temperature is detected by an electronic probe and can be
preset when programming the electronic card.
4.5 Connection for the Master/slave function
This operation must be carried out solely by authorized personnel.
Before beginning any operations ensure that the electricity
supply of the distributor has been disconnected.
POWER SUPPLY BOARD CONFIGURATION FOR SLAVE CONNECTION
All ARIA Slave dispensers are configured with a jumper inserted only on pin
1 of input connector (A). With model "B", the jumper must be positioned on
pins 1 and 2 of input connector (B).
Hot drink vending
machine (BVM9xx)
Master Slave is connected using
the connector holding plate situ-
ated on the back of the machine,
as shown in the figure.
When all the connections have
been completed, the cables must
be secured in position using the
cable retainers placed underneath
the connector holding plate.
16
Use a cable based on the speci-
fication shown on the portal.
ENGLISH