Technical Data:
High-strength plastic housing with transpa-
rent, splinter-proof plastic cover.
Housing colour:
Housing dimensions
(w x h x d):
approx. 92.5 x 250 x 98 mm
Emergency control element
illuminated:
as per DIN VDE 0660
3 Display LEDs:
red, green and yellow
Acoustic signal
Cylinder for key switch
single-profile cylinder
with locking bit position
(Order ref. no. 1337-10-7)
1 Luminescent plastic film liner for emergency
switch identification
1 Self-adhesive luminescent pictogram
Type of protection:
Humidity rating:
Ambient temperature range:
Installation position:
1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0
1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0
1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0
1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0
16
Control functions/status indicating signals
LED displays
RAL 6032
Red
Green
part 200/part 207
Green/yellow
( Euro-standard
90 ° left
Green / yellow or
red / yellow
Key switch operating positions
DIN 40050-IP 20
Brief clockwise operation =
DIN 40050-F
6° to 40° C
Vertical
Brief anti-clockwise operation =
If the operating status of the system is switched
to emergency unlocking, the status can be
reset by briefly turning the key switch clockwise.
A prerequisite for this is that the cause of the
„Emergency unlocking" signal, which has been
given by the emergency switch or other external
contacts, be reset (see section on resetting/
relocking).
max. 1050 mm
Installation:
The door terminal must be mounted beside the door
frame and at the height of the door handle in such a
way that the centre of the emergency switch does not
exceed a maximum height of 1050 mm above the
finished floor level.
= escape door locked,
2 door monitoring
operative
= escape door unlocked,
2 door monitoring
inoperative
= escape door emergency
unlocked
„Emergency unlocking"
signalled
= sabotage,
„Sabotage" signalled
escape door locking „on",
door monitoring „on"
escape door unlocking „off",
door monitoring „off".