21. Technical data
a) Basis station
Power supply .......................................................... 4 type AAA/Micro batteries
Temperature measuring range ............................ 0 °C to +60 °C
Resolution ...................................................... 0.1 °C
Accuracy ........................................................ ±1 °C
Humidity measuring range ................................... 10% to 99% relative humidity
Resolution ...................................................... 1% relative humidity
Accuracy ........................................................ ±5% relative humidity
Number of outdoor sensors ................................. Up to 8 (3 are included in the delivery,
Dimensions.............................................................. 115 x 125 x 22.5 mm (W x H x D)
Weight ...................................................................... 142.2 g
b) Outdoor sensor (3 enclosed)
Power supply .......................................................... 2 type AAA/Micro batteries
Transmission frequency ........................................ 433 MHz
Transmitter range ................................................... Up to 100 m (see chapter "Range")
Measuring interval................................................. Approx. 1 minutes
Temperature measuring range ............................ -40 °C to +60 °C
Resolution ...................................................... 0.1 °C
Accuracy ........................................................ ±1 °C
Humidity measuring range ................................... 10% to 99% relative humidity
Resolution ...................................................... 1% relative humidity
Accuracy ........................................................ ±5% relative humidity
Dimensions.............................................................. 45 x 110 x 20 mm (W x H x D)
Weight ...................................................................... 51.2 g
up to 5 others can be ordered as acces-
sories)
49