G 2
B AUDIO AND VIDEO DOOR ENTRY SYSTEM - PROXIMITY READER MODULE
SAFETY PRECAUTIONS
-
Always disconnect the power supply before installing or making modifications to the devices.
-
The fitting and handling of these devices must be carried out by
-
The wiring must run at least 40 cm away from any other wiring.
( )
CHARACTERISTICS
*
-
Proximity key reader module and phone book navigation for GB2 coded door panel systems.
-
Can be combined with 'Nexa Modular' and 'Inox Modular' door panels.
-Enables activation of the door release connected to Relay 1 of the EL632/GB2A module using the
proximity key reader.
-Using the selection buttons, it enables the user to scroll through the phone book displayed on the
EL3422/GB2 TFT screen module and make a call by pressing the bell key.
( )
DESCRIPTION OF THE MODULE
*
a
b
c
d
a. Front.
b.
Proximity key reader.
c.
Bell button.
d.
Selection buttons.
( )
CONNECTION OF THE MODULE
*
N3401/GB2
( )
For more information, see the "TCODE/CA GB2 user manual (code
*
https://doc.golmar.es/search/manual/50122371
2
authorised personnel
.
e
f
e. Back.
f.
Socket for connection with the EL632/GB2A.
_
+
C1 NA1
AP-
AP+
NA2
C2 AP+ AP- P1 P2 BUSBUS
Relay 1
Relay 2
12Vdc
EL632/GB2A
50122371)".
G 2
B AUDIO AND VIDEO DOOR ENTRY SYSTEM - PROXIMITY READER MODULE
PROGRAMMING THE DOOR PANEL
( )
*
Activating MASTER CARD keys on the door panel:
(Step 1)
_
+
C1 NA1
AP-
AP+
NA2
Relay 1
Relay 2
12Vdc
With the EL632/GB2A module connected and operating, set its DIP
(Step 2)
4 to the OFF position. (At the end of programming, it must be
returned to its initial position, ON for buildings/OFF for houses).
(Step 3)
Using the DIP 4 located on the EL632/GB2A module, perform the following sequence:
At the end of the sequence, communication indicator
illuminate. You then have 10 seconds to perform the following step.
(Step 4)
Hold the MASTER CARD ADD key near to the proximity reader located on the
N3401/GB2 module and, once stored, communication indicator
the door panel will emit a confirmation tone.
Then hold the MASTER CARD DELETE key near to the proximity reader located on
the N3401/GB2 module and, once stored, door open indicator
door panel will emit a confirmation tone.
(Step 5)
Set the DIP 4 on the EL632/GB2A module to the initial position and remove the short
circuit between AP+ and AP-:
ON for buildings
OFF for houses
The same MASTER CARD keys can be added to as many door panels as necessary.
Proximity keys for residents can then be added/deleted as indicated in the following section.
( )
For more information, see the "TCODE/CA GB2 user manual (code
*
https://doc.golmar.es/search/manual/50122371
Cause a short circuit between the AP+ and AP-
terminals of Relay 1 on the EL632/GB2A module.
To the FA-GB2/A
power supply.
and door open indicator
will turn off and
will turn off and the
_
+
C1 NA1
AP-
AP+
NA2
Relay 1
Relay 2
12Vdc
50122371)".
3