PH CONTROLLER
1
Choose an area which is easily accessible, close to the electronic filtration box. Install the pH
controller vertically, far enough away from the pool to respect the regulatory distances in force in
the country of installation. Do not cover it.
The pH controller must be permanently connected to the filtration controller and slaved to the
pump contactor. Do not use an extension cord with a plug or use a plug to connect the unit. Turn off
the differential circuit breaker beforehand. Ensure that the controller switches off when the
filtration pump stops.
ACCESSORIES
2
Place the first pipe collar in the middle of a horizontal pipe, a minimum length of 40 cm. Adjust the
opening ½'' towards the top. Mark then pierce the pipe. Mount the probe holder on the pipe collar
with Teflon.
Remove the rubber protection from the pH probe then mount it on the probe holder. Ensure it is not
stuck in the pipe.
Connect the cable from the pH probe (BNC plug) to the bottom of the controller. Keep it away from
all other electric cables to avoid any electromagnetic disturbance which may distort measurements.
Place the second pipe collar a minimum of 50 cm from the first. Adjust the opening preferably 1/2''
towards the bottom. Mark then pierce the pipe. Mount the injection connector ½ ''on the pipe collar.
The injection connector should be as close as possible to water pushing in to the pool.
Connect the suction strainer to the pH pump with a part of the tubing supplied. Use the direction of
the arrows which are on the cover of the pH pump.
Connect the output of the pH pump with the remaining hose.
14