English
DIP Switch Tables
Serial Interface (DIP switch 1)
SW
Function
1-1
Data reception error
1-2
Receives buffer
capacity
1-3
Handshaking
1-4
Data word length
1-5
Parity check
1-6
Parity selection
1-7
Selects transmission speed. (See table below.)
1-8
Transmission speed
Transmission speed (bps)-bits per second
Adjustable by control commands
4800
9600
19200
*:
When DIP Switches 1-7 and 1-8 are on, the transmission
speed can be selected from one of seven speeds:
2400, 4800, 9600, 19200, 38400, 57600, and 115200 bps
by control commands.
Serial Interface (DIP switch 2)
SW
Function
2-1 Handshaking
(BUSY condition)
2-2 Reserved (Do not
change)
2-3
Selects print density/
2-4
Low power comsumption
mode
2-5 [When TM-T88IV-
compatible mode is
enabled]
Setting the conditions
that cancels the receive
buffer BUSY state (This
function is effective when
the receive buffer
capacity is set to 4KB.
[When TM-T88IV-
compatible mode is
disabled]
Reserved
2-6 Reserved (Do not
change)
2-7 I/F pin 6 reset signal
2-8 I/F pin 25 reset signal
iv
ON
OFF
Ignored
Prints "?"
45 bytes
4KB
XON/XOFF
DTR/DSR
7 bits
8 bits
Enabled
Disabled
Even
Odd
1-7
1-8
*
ON
ON
OFF
ON
ON
OFF
OFF
OFF
ON
OFF
Receive
Offline or
buffer full
Receive
buffer full
–
Fix to OFF
See Table A.
Cancels the
Cancels the
BUSY state
BUSY state
when the
when the
remaining
remaining
capacity of
capacity of
the receive
the receive
buffer
buffer
reaches 138
reaches 256
bytes.
bytes.
–
–
–
Fix to OFF
Enabled
Disabled
Enabled
Disabled
Interface other than Serial (DIP switch 1)
SW
Function
1-1
Auto line feed
1-2
Receives buffer
capacity
1-3
[When TM-T88IV-
compatible mode is
enabled]
Selects paper sensor
to output paper-end
signal
[When TM-T88IV-
compatible mode is
disabled]
Reserved
1-4
Error signal output
1-5~
Reserved
1-8
Interface other than Serial (DIP switch 2)
SW
Function
2-1 Handshaking
(BUSY condition)
2-2 Reserved (Do not
change)
2-3
Selects print density/
2-4
Low power
comsumption mode
2-5 [When TM-T88IV-
compatible mode is
enabled]
Setting the conditions
that cancels the receive
buffer BUSY state (This
function is effective
when the receive buffer
capacity is set to 4KB.
[When TM-T88IV-
compatible mode is
disabled]
Reserved
2-6
Reserved (Do not
2-7
change)
2-8 I/F pin 31 reset
(Do not change)
Table A
Print density/low power
Print density (Standard)
58 mm paper width model:
Print density (Standard)
80 mm paper width model:
Low power consumption mode
Print density (Darker than standard)
Print density (Dark)
ON
OFF
Always
Always
enabled
disabled
45 bytes
4 KB
Disabled
Roll paper end
sensor enabled
Roll paper
near-end
sensor enabled
–
–
Disabled
Enabled
–
–
ON
OFF
Receives
Offline or
buffer full
receives
buffer full
–
Fixed to OFF
See Table A.
Cancels the
Cancels the
BUSY state
BUSY state
when the
when the
remaining
remaining
capacity of
capacity of
the receive
the receive
buffer
buffer
reaches 138
reaches 256
bytes.
bytes.
–
–
–
Fixed to OFF
Fixed to ON
–
SW 3
SW 4
OFF
OFF
ON
ON
ON
OFF
OFF
ON