OM_E0X7300401-00.book Page 6 Tuesday, March 13, 2018 5:14 PM
13
AUTO RESTART OPERATION
To automatically restart the air conditioner after the power failure (Power of the unit must be
on.)
Setting
1. Press and hold the TEMPORARY button on the signal receiving unit for 3 seconds to
set the operation. (3 beep sound and OPERATION lamp blink 5 time/sec for 5
seconds)
2. Press and hold the TEMPORARY button on the signal receiving unit for 3 seconds to
cancel the operation. (3 beep sound but OPERATION lamp does not blink)
14
QUIET OPERATION
To operate at super low fan speed for quiet operation (except in DRY mode)
Press
: Start and stop the operation.
Note: Under certain conditions, QUIET operation may not provide adequate cooling due to
low sound features.
15
COMFORT SLEEP OPERATION
For comfortable sleep, automatically control air flow and automatically turn OFF.
Press
: Select 1, 3, 5 or 9 hrs for OFF timer operation.
Note: The cooling operation, the set temperature will increase automatically 1 degree/hour
for 2 hours (maximum 2 degrees increase). For heating operation, the set temperature
will decrease.
SELF CLEANING OPERATION (COOL
16
AND DRY OPERATION ONLY)
To protect bad smell caused by the humidity in the indoor unit.
1. If the
button is pressed once during "Cool" or "Dry" mode, the fan will
continue to run for other 30 minutes, then it will turn off automatically. This will reduce
the moisture in the indoor unit.
If the time of "Cool" or "Dry" operation is less than 10 minutes, the self cleaning
operation is not performed.
2. To stop the unit immediately, press the
OPERATION AND PERFORMANCE
17
1. Three-minute protection feature: To prevent the unit from being activated for 3 minutes
when suddenly restarted or switched to ON.
2. Preheating operation: Warm up the unit for 5 minutes before blowing warm air.
3. Warm air control: When the room temperature reaches the set temperature, the fan
speed is automatically reduced and the outdoor unit will stop.
4. Automatic defrosting: Fans will stop during defrost operation.
5. Heating capacity: Heat is absorbed from outdoor and released into the room. When the
outdoor temperature is too low, use another recommended heating apparatus in
combination with the air conditioner.
6. Consideration for accumulated snow: Select the position for outdoor unit where it will not
be subjected to snow drifts, accumulation of leaves or other seasonal debris.
Air conditioner operating conditions
Temp.
Outdoor Temperature
Operation
Heating
Cooling
Dry
Refer to the Installation Manual of the outdoor unit.
18
TROUBLESHOOTING (CHECK POINT)
The unit does not operate.
The power main switch is turned off.
The circuit breaker is activated to cut off
the power supply.
Stoppage of electric current
ON timer is set.
more 2 times within 30 seconds.
Room Temperature
Less than 28°C
21°C ~ 32°C
17°C ~ 32°C
Cooling or Heating is abnormally low.
The air filter (Locally procured) is blocked
with dust.
The temperature has been set
improperly.
The windows or doors are opened.
The air inlet or outlet of the outdoor unit is
blocked.
The fan speed is too low.
The operation mode is DRY.
6
19
REMOTE CONTROL A-B SELECTION
To separate using of remote control for each indoor unit in case of 2 air conditioners are
installed nearly.
Remote Control B Setup.
1. Press TEMPORARY button on the signal receiving unit to turn the air conditioner ON.
2. Point the remote control at the signal receiving unit.
3. Push and hold
button on the Remote Control by the tip of the pencil. "00" will be
shown on the display.
4. Press
during pushing
. "B" will show on the display and "00" will
disappear and the air conditioner will turn OFF. The Remote Control B is memorized.
Note: 1. Repeat above step to reset Remote Control to be A.
2. Remote Control A has not "A" display.
3. Default setting of Remote Control from factory is A.
A
B
EN

Publicité

Table des Matières
loading

Table des Matières