The outlet for the CAPXM MUST be an external dedicated 120 Vac outlet.
INTRODUCTION
Refer to the table below for maximum wire run distances. This outlet should
be wired back to its own 10 Amp minimum circuit breaker.
WIRE SPECIFICATION
14 AWG
16 AWG
INTRODUCTION
18 AWG
1.
Connect 14-18 AWG wire to the stripped secondary DC output wires on
the power supply. Black is negative and red is positive.
2.
Remove the PWR INPUT terminal block from the Control Board.
3.
Connect the power supply wires to the PWR INPUT terminal block (red
to +24V and black to GND). Reattach the terminal block to the Control
Board.
4.
Plug the power supply into a 120 Vac outlet after all connections have
been made.
NOTE: The green LED on the door board will blink and the green
LEDs on the Control Board will light solid when powered up. The
CAPXM will display the LiftMaster logo while booting up. When
boot up is complete, the user interface will appear.
5.
Close the CAPXM door.
POWER INPUT
Control Board
PRE-INSTALL
PRE-INSTALL
MAXIMUM RUN DISTANCE
Up to 300 feet (91.4 m)
Up to 200 feet (60.9 m)
PRE-INSTALL
Up to 100 feet (30.4 m)
NOTE: If the power supply is installed
outdoors, the power supply must have
its own approved NEMA 4 Rated
weatherproof electrical enclosure.
Use conduit from the power supply
enclosure to the controller enclosure.
Power Supply
INSTALL

NETWORK

INSTALL
NETWORK
INSTALL
NETWORK
Dedicated 10 Amp Minimum Circuit
120 Vac
Dedicated Outlet
15
ACCESS CONTROL
• DO NOT use ANY power supply other
ACCESS CONTROL
than those supplied with your CAPXM.
• DO NOT power electronic strikes and
latches with the same power supply
used to power the access control panel;
doing so will cause DAMAGE to the
CAPXM. Use ONLY a UL listed burglar
alarm or access control system to
ACCESS CONTROL
power electronic strikes and latches.
• DO NOT connect the power supply to a
switched outlet or otherwise controlled
AC outlet.
• DO NOT connect the power supply to
the 120 Vac outlet until ALL wiring is
completed.
• Install the transient noise suppression
device (MOV) supplied with the CAPXM
for AC powered devices and Diode for
DC powered devices.
• DISCONNECT the power supply from
the 120 Vac outlet prior to removing or
attaching the terminal block to the
Control Board.