INTRODUCTION
1

Remove Knockouts

1.
Prepare the work surface by laying down a cloth or
INTRODUCTION
other protective material.
2.
Lay the CAPXM face down on the protective
material.
3.
Identify which knockouts need to be removed
based on your application.
INTRODUCTION
4.
Use a center punch tool to remove the knockouts
from the outside of the box inward using an
appropriately sized punch and hammer. NOTE:
Be careful when removing the knockouts to avoid
damaging the CAPXM components.
E = Electrical Wiring
P = Pedestal Mount
R = Recess/Surface Mount
S = Security+ 2.0
Radio Antenna
®
W = Wi-Fi
PRE-INSTALL
PRE-INSTALL
PRE-INSTALL
®
Antenna
INSTALL
To prevent damage to the CAPXM from moisture or water:
INSTALL
• DO NOT install during rain. Internal components MUST be
kept from of water and moisture.
• BEFORE opening the front cover of the CAPXM, remove ANY
accumulated water from the top of the CAPXM.
To prevent damage to ANY internal components:
• DO NOT attempt to remove the knockouts with a hammer.
INSTALL
Banging on the knockouts may result in shock to the circuit
boards, which could cause permanent damage.