SYMPTOM
Red LED indicator light is on and the
tool did not operate
Tool operates normally but did not drive
the nails to flush
Fan does not run and the indicator light
is red
Battery does not accept charge or the
charger get hot when charging
Charger get hot, make noise or start to
smoke
Work contact element is not fully
depressed and the tool can not be used
Tool will not cycle, the indicator LED is
green and the fan runs
Tool operate normally, but no nail is dri-
ven
Combustion chamber is not returning to
start position
Driver did not return to initial position,
miss fire frequency get higher than
usual
Tool appears to be loosing power
For failure other than above situation, please stop using the tool and contact your local dealer for
service.
4. TROUBLE SHOOTING
- Battery charge might be too low.
- Replace battery with a fully charged one.
- Adjust the depth of drive setting to deepest.
- Clean the cylinder with proper cleaner.
- Check fuel cell and replace as required.
- Depress the safety and hold for 1 minute before activate the
trigger. If the tool did not fire, there might be seal leaking over
the combustion chamber. Send to service center near you.
- The battery is out. Replace the battery with a fully charged
one.
- The battery node is dirty or oily. Clean the battery node with
clean cloth.
- If all above did not work, send to service center near you.
- Replace the battery. If this action corrects the problem, the
battery is damaged or exhausted.
- Replace the charger if the battery works fine on tool but can
not be charged on charger.
- The charger is damaged and should not be used any more.
Unplug the charger immediately and replace it with a new
charger.
- The work contact element is bend or the track of the safety
mechanism is sticky to the dirt build up. Clean the safety
track. Repair or replace the work contact element.
- Lock out mechanism is active. Load more nails.
- Run out of fuel, replace a new fuel cell.
- Spark wire is loose, check the spark wire by removing the
cap.
- Sparke plug is dirty. Clean the spark plug.
- If all above did not work, send to service center near you.
- Wrong type of nails was used. Please change to correct nail
spec.
- The cylinder needs cleaning.
- Nail is jammed, clean the jammed nail before use.
- The nail pusher did not engage properly with the nail strip.
Adjust to fully engagement.
- The work contact element is bending or dirty. Check the
work contact element and repair or replace it. Clean the
safety track.
- Check and replace fuel cell.
- Clean the tool with proper cleaning fluid.
- Check for piston ring wear status.
- The tool maybe over heated. Clean or replace the intake air
filter.
- Check fuel cell.
- Clean or replace air intake filter.
- Check spark plug wire.
- Clean the tool with proper cleaning fluid.
13
COUNTER MEASURES